background image

Section 8  

Warranty, Product Return and

Technical Assistance

This product is warranted against defects in material or workmanship, and
at the option of the manufacturer or distributor, any defective product will
be repaired or replaced at no charge, or the purchase price will be refunded
to the purchaser, provided that: (a) the warranty claim is made in writing
within the period of time specified on the warranty card, (b) proof of
purchase by bill of sale or receipted invoice is submitted concurrently with
the claim and shows that the product is within the applicable warranty
period, and (c) the purchaser complies with procedures for returns set
forth in the general terms and conditions contained in the manufacturer's
or distributor's most recent catalog.

This warranty shall not apply to: (a) defects or damage resulting from: (i)
misuse of the product, (ii) use of the product in other than its normal and
customary manner, (iii) accident or neglect, (iv) improper testing,
operation, maintenance, service, repair, installation, or storage, (v)
unauthorized alteration or modification, or (b) post-expiration dated
materials.

THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE
PURCHASER, AND THE MANUFACTURER AND DISTRIBUTOR
DISCLAIM ALL OTHER WARRANTIES, WHETHER EXPRESS,
IMPLIED, OR STATUTORY, INCLUDING WITHOUT
LIMITATION, WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. NO EMPLOYEE,
AGENT, OR REPRESENTATIVE OF THE MANUFACTURER OR
DISTRIBUTOR IS AUTHORIZED TO BIND THE
MANUFACTURER OR DISTRIBUTOR TO ANY OTHER
WARRANTY. IN NO EVENT SHALL THE MANUFACTURER OR
DISTRIBUTOR BE LIABLE FOR INCIDENTAL, INDIRECT,
SPECIAL OR CONSEQUENTIAL DAMAGES.

The warranty period for this product is one (1) year from date of purchase.

FH100 Precision Variable-Speed Peristaltic Pump System Operating Manual

8-1

Cole-Parmer

Warranty

Summary of Contents for 77722-00

Page 1: ...TIC PUMP SYSTEM Model 77722 00 Model Nos 77722 00 77722 02 A 1299 7292 Edition 01 US Canada only Toll Free 1 800 MASTERFLEX 1 800 637 3739 Outside US Canada 1 847 549 7600 1 847 381 7050 E mail techin...

Page 2: ...Cole Parmer Instrument Company LLC All rights reserved NORPRENE PHARMED and TYGON Reg TM Saint Gobain Performance Plastics Corp Trademarks bearing the symbol in this publication are registered in the...

Page 3: ...ed in the instructions the protection provided by the equipment may be impaired CAUTION Risk of Danger Consult Operator s manual for nature of hazard and corrective actions CAUTION Risk of crushing Ke...

Page 4: ...100 Pump System is equipped with a current limiting circuit that will slow the motor down if any of the following conditions exist a Tubing that is too hard is loaded in the pump b Incorrect tubing si...

Page 5: ...bing 3 1 Tubing Inspection and Replacement 3 2 Pump Controls 3 2 External Operation 3 3 External Inputs 3 4 MAINTENANCE 4 1 Cleaning 4 1 TROUBLESHOOTING 5 1 Troubleshooting Chart 5 1 REPLACEMENT PARTS...

Page 6: ......

Page 7: ...tors and Connectors 1 2 Tube Loading Upper Retainer 3 1 Tube Loading Lower Retainer 3 2 DB9 Pin Configuration with Wiring Scheme 3 3 FH100 Precision Variable Speed Peristaltic Pump System Operating Ma...

Page 8: ......

Page 9: ...1 Cole Parmer Section 1 Introduction The FH100 Precision Variable Speed Peristaltic Pump System provides continuous pumping of fluids while power is supplied These Pump Systems are ETL and CE certifi...

Page 10: ...before reversing direction D INTERNAL EXTERNAL KEY This key changes the mode of operation for the drive Internal Local operation throught the front panel keypad is designated by INT while external Rem...

Page 11: ...ate is determined by the size of the tubing in the Pump Head When tubing links are used best performance will be achieved when input and output tubing connected to the link are the same ID as the link...

Page 12: ......

Page 13: ...n wet locations as defined by EN61010 1 If the product is not used in a manner specified in the instructions the protection provided by the equipment may be impaired The Pump Head has two tubing retai...

Page 14: ...inside the occlusion bed of the pump to the outside of the occlusion bed to the suction side of the pump This will avoid excessive tubing wear at any specific point Always move the worn tubing to the...

Page 15: ...ts permit control of the pump by remote equipment or accessories Figure 3 3 shows the signal locations of the connector Pin No Description 1 Speed Control Voltage Input 0 10V input 2 Speed Control Cur...

Page 16: ...g the speed from the front panel is desired with external Start Stop contact operation the INT EXT key must again be in the EXT position In addition Jumper A should be in place Jumper A connects pin 4...

Page 17: ...pump and when the ON OFF switch is in the ON position If this condition occurs remove power from the unit and remove the fuse from the fuse holder located on the rear of the pump Replace the fuse wit...

Page 18: ......

Page 19: ...rd Verify that the pump head door is securely shut Check the tubing Tubing should be snug but not tight against the rollers Verify that the mode EXT INT is set correctly Error XX is displayed on the s...

Page 20: ......

Page 21: ...1 64 1 Line Cord 115V United States 50001 68 1 Line Cord Israel 50001 69 1 Line Cord Europe 50001 70 1 Line Cord England 50001 72 1 Line Cord Switzerland 50001 74 1 Line Cord Italy 50001 76 1 Line Cor...

Page 22: ......

Page 23: ...an 6562 ft 2000 m Pollution Degree Pollution degree 2 indoor use lab office Construction Dimensions L W H 12 5 in 11 in 6 in 31 8 cm 27 9 cm 15 2 cm Weight 5 67 kgs 12 5lbs Color Light Grey 5 Black Ma...

Page 24: ......

Page 25: ...s or damage resulting from i misuse of the product ii use of the product in other than its normal and customary manner iii accident or neglect iv improper testing operation maintenance service repair...

Page 26: ...ions before returning the product either within or outside of the warranty period When returning the product please state the reason for the return For your protection pack the product carefully and i...

Page 27: ......

Page 28: ...0 MASTERFLEX 1 800 637 3739 Outside US Canada 1 847 549 7600 1 847 381 7050 www masterflex com www coleparmer com E mail techinfo coleparmer com EN809 manufactured by Cole Parmer Instrument Company LL...

Reviews: