3.6 AC Installation (220/110 Volts ISO 13297)
DANGER
The on-board AC installation is protected by a circuit breaker and is equipped with an RCD (residual
current device). Their correct functioning should be tested monthly.
The wiring for any additional on-board AC accessories must be done by a professional, with new,
appropriately sized circuit breakers.
If maintenance is being carried out
with the boat out of the water, switch it to the ‘’ON’’ position to ensure
earthing protection
via the shore power.
Location of the AC shore power circuit breaker: Port engine compartment.
If the vessel is equipped with a generator, an RCD will be installed near to it. The same applies if the vessel
is fitted with a DC/AC converter.
The circuit breakers for the various AC circuits are housed in an electrical box beneath the chart table.
Shore power socket