Data logger operating manual

3

EN

Battery compartment

Battery cover

PC connection USB type micro B

Network connection RJ45

Mount track for fastening

LCD display:

Measured value row 1

Measured value row 2

Measured value row 3

Display symbol for active acoustic signal

Display symbol for active network connection

Display symbol for active USB connection

Display symbol for power supply over a network

Display symbol for power supply over USB

Display for battery level

Display for mode marker

Display for active measured value recording

Display for inactive measured value recording

Display for date

Display for time

Mode selection button

Data logger with internal sensors (THI /THIP /TCO)

4. Scope of supply

The following components are included in the standard scope of supply:

Data logger

USB connection cable

CD-ROM with operating manual, SmartGraph software
and software manual

Factory certificate

3. Equipment






Summary of Contents for TCO

Page 1: ...BA THI THIP TCO 05 EN v1 0 Modification rights reserved Turfschipper 114 2292 JB Wateringen Tel 31 0 174 272330 www catec nl info catec nl Turfschipper 114 2292 JB Wateringen Tel 31 0 174 272330 www...

Page 2: ...table recording or re quest intervals then saved and transmitted to a connected PC The measuring device may only be used for this intended use while complying with specified technical data Any other u...

Page 3: ...Display symbol for power supply over a network Display symbol for power supply over USB Display for battery level Display for mode marker Display for active measured value recording Display for inacti...

Page 4: ...y state the power consumption is minimal because measured values cannot be requested or shown M53 M52 M51 M4 M3 M2 M1 Selection of the operating mode M1 Display of the operating mode M1 5 Preparation...

Page 5: ...on is ac tivated then software configuration and data reading from the data logger can be carried out over the network A signal which is broadcast from the data logger over UDP allows the SmartGraph s...

Page 6: ...minimum measured value min maximum meas ured value max and average measured value mid In total there are 24 meas uring channels available for your THI data logger as shown in table 1 Model THIP The TH...

Page 7: ...ed in the software manual 8 Alarm function 8 1 Alarm configuration An alarm function can be configured in the measuring device administration for each of the measuring channels selected for display or...

Page 8: ...ed batteries in the household rubbish or throw them in the fire instead dispose of them according to the relevant legal requirements 9 2 Deleting measured data The detected measured data are permanent...

Page 9: ...r at 25 C 0 5 hPa Screen resolution 0 1 hPa CO2 concentration Operating principle NDIR Measuring range 0 5 000 ppm Accuracy 50 ppm 3 measured value at 20 C and 1 013 mbar Screen resolution 1 ppm Long...

Reviews: