28 - 40
021774/07/14
Parameter description:
99
generic 'id' (THIES interpreter)
0
Broadcast slave address (MODBUS RTU Interpreter)
Value range:
0 to 99 (THIES interpreter)
1 to 247 (MODBUS RTU interpreter)
Initial value:
0 (THIES Interpreter)
1 (MODBUS RTU Interpreter)
6.3.8 Command KY
<id>KY<parameter><CR>
Key/password
Access:
Read / write
Description:
Through
of the command “KY” the value for the key (password) is set. For
the change of parameters the required password must be used.
Parameter description:
0
no password
234
password for user level
Value range:
0 / 234
Initial value:
0
6.3.9 Command LC
<id>LC<parameter><CR>
LED control
Access:
Read / write
Description:
The command LC is used to specify the mode for control of the blue LED.
Parameter description:
Parameter
Description
0
LED (blue) indicates wind speed
1
LED (blue) is dark
Examples:
LED dark blue:
"00LC1\r"
LED blue indicates wind speed:
"00LC0\r"
Value range:
0 / 1
Initial value:
0