4
UK
Troubleshooting
If your Caterlite appliance develops a fault, please check the following table before making a call to the
Helpline.
Technical Specifications
Electrical Wiring
This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
•
Live wire (coloured brown) to terminal marked L
•
Neutral wire (coloured blue) to terminal marked N
•
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
Fault
Probable Cause
Action
The appliance is not working
The appliance is not switched on Check the appliance is plugged in correctly
and switched on
Plug and lead are damaged
Call Caterlite agent or qualified technician
Fuse in the plug has blown
Replace the plug fuse
Power supply
Check power supply
Internal wiring fault
Call Caterlite agent or qualified technician
Heating element has expired
Call Caterlite agent or qualified technician
Model
Voltage
Power
Current
Maximum
bread width
Dimensions
h x w x d (mm)
Weight
GH439
220-240V
50Hz
1580-1800W
7.2A
35mm approx.
200x280x286
3.1kgs