e

STORAGE

There is no limitation on the storage of the appliance indoors provided that the cylinder is removed 

from the appliance. Between uses:

•  Turn control knob OFF
•  Turn gas cylinder OFF
Store heater upright in an area sheltered from direct contact with inclement weather (such as rain, 

sleet, hail, snow, dust and debris).
During periods of extended inactivity or when transporting:

•  Turn control knob OFF.
•  Disconnect gas cylinder and move to a secure, well ventilated location outdoors. DO NOT store in a 

location that will exceed 50°C.

Store heater upright in an area sheltered from direct contact with inclement weather (such as rain, 

sleet, hail, snow, dust and debris).
If desired, cover heater to protect exterior surfaces and to prevent build up in air passages.

Note: Wait until heater is cool before covering

IF THE PROBLEM IS:

AND THIS CONDITION EXISTS:

THEN DO THIS: 

Pilot won’t light 

Cylinder valve is closed

Open valve

Blockage in orifice or pilot tube

Clean or replace orifice or pilot tube

Air in the gas line

Open gas line and bleed it (pressing 

control knob in) for not more than 

1-2 minutes or until you smell gas

Low gas pressure

Gas cylinder low or empty

Igniter fails

Use match to light pilot, and obtain 

new igniter and replace. ( See below 

pictures)

Pilot won’t stay lit 

Dirt build up around pilot 

Clean dirt from around pilot

Connection between gas valve and 

pilot assembly is loose

Tighten connection and perform 

leak test

Bad thermocouple

Replace thermocouple

Burner won’t light 

Gas pressure is low

Replace gas cylinder

Blockage in orifice

Clear blockage

Control knob is not in "ON" position Turn control knob to "ON" position

Burner flame is low

Note: Do not operate heater below 

5°C (40°F)

Gas pressure is low

Replace gas cylinder

Note: Do not operate heater below 

5°C (40°F)

Replace gas cylinder

Supply hose is bent or kinked 

Straighten hose and perform leak 

test on hose

Control knob is fully " ON" 

Turn control knob to "OFF", let it 

cool to room temperature & check 

burner and orifices for blockage

Emitter glows uneven

Note: Bottom 2.5cm of emitter nor-

mally does not normally glow

Gas pressure is low 

Replace gas cylinder

Base is not on a level surface 

Place heater on a level surface 

Heater not level

Level heater

Carbon build-up 

Dirt or film on reflector and emitter  Clean reflector and emitter 

Thick black smoke 

Blockage in burner

Turn control knob to "OFF", let it 

cool to room temperature and 

remove blockage and clean burner 

inside and outside.

TROUBLESHOOTING

Summary of Contents for SILVERINO

Page 1: ...SILVERINO item 13 936 e Patio Heater c Plynov z i s Plynov iari...

Page 2: ...peration if there is evi dence of excessive abrasion or wear or if the hose is damaged and that the replacement hose assem bly shall be that specified by the manufacturer The heater should be inspecte...

Page 3: ...er assembly Step 3 Connecting hose and regulator if supplied to the burner assembly Put gas cylinder on the base and connecting regulator to a gas cylinder then assembly 2 cylinder belts and ensure ga...

Page 4: ...ition The gas cylinder must always be used in an upright position Close the heater control knob by turning fully clockwise Close the gas cylinder tap and then attach the regulator onto the gas cylinde...

Page 5: ...ce Respect the minimum clearances from combus tible materials GAS LEAKAGE TEST NEVER USE A NAKED FLAME TO CHECK FOR LEAKS NEVER LEAK TEST WHILE SMOKING The gas connections on this appliance are leak t...

Page 6: ...sembly dry at all times If the gas control is exposed to water in any way DO NOT try to use it It must be replaced Airflow must be unobstructed Keep controls burner and circulation air passageways cle...

Page 7: ...Gas cylinder low or empty Igniter fails Use match to light pilot and obtain new igniter and replace See below pictures Pilot won t stay lit Dirt build up around pilot Clean dirt from around pilot Con...

Page 8: ...open The surface area is the sum of the walls surface Product Name Area Patio Heater Country Code CH ES FR GB GR IE IT PT BE CY CZ DK EE FI GR IT LT LV MT NL NO SE SI SK BG RO TR AT CH DE CZ FR GB GR...

Page 9: ...vystaveni p i vysok teplot zejm na pop lenin a z n t Je zak z no v et oble en a tak um s ovat jin ho lav nebo v bu n kapaliny a materi ly v bl zkosti topidla Je zak z no prov d t jak koliv pravy na to...

Page 10: ...i roubujte jej pomoc 5 ks roub a podlo ek M5 10 Upozorn n Pro spr vn zav r n dve p izvedn te jednou rukou horn st s ho kem a a pot dot hn te v ech 5 roub Krok 3 P ipojte k ho ku hadici s reduk n m ve...

Page 11: ...m st mimo otev en pla men nebo jin zdroj zap len P esn pokyny k pou it plynov lahve z sk te od sv ho dodavatele plynu Plynov l hev mus b t v dy pou v na p epravov na i skladov na ve svisl poloze P ed...

Page 12: ...ho kem na sv m m st Respektujte minim ln vzd lenosti od ho lav ch materi l ZKOU KA T SNOSTI Nikdy nepou vejte ohe p i zkou ce t snos ti Nikdy neku te p i zkou ce t snosti Plynov p pojky p stroje jsou...

Page 13: ...lo k ucp n vzduchov ho otvoru Na vstupuje pro p ipojen k ventilu opat en p evle nou matic W 21 8 x 1 14 L a na v stupu hadicovou koncovkou pro hadici na PB s vnit n sv tlost 8mm nebo z vitem G 1 4 L T...

Page 14: ...ada e v poloze PILOT nechejte odvzdu nit alespo 2 minuty nebo dokud neuc t te plyn Mal tlak plynu Plynov l hev je pr zdn Selh n zapalov n Pro zap len pou ijte sirky Ho k zhas n Ne istoty okolo PILOT h...

Page 15: ...0 I3P 37 I3P 50 Velikost trysky 1 64mm 1 64mm 1 55m 1 64mm 1 60mm Tepeln v kon 11kW 11kW 13 5kW 11kW 12 5kW Spot eba plynu 0 8kg h 0 8kg h 0 9kg h 0 8kg h 0 9kg h Model H1109B V robce Ningbo Innopower...

Page 16: ...V robek je v souladu s n e uveden mi p edpisy Sm rnice Evropsk ho parlamentu a Rady 2016 426 ES a normami EN 14543 2005 A1 2007 Certifik t 0063CO7365 0063 19 V robce Ningbo Innopower Hengda Metal Prod...

Page 17: ...kej teplote najm pop len n a z palov Je zak zan ve a oble enie a tie umiest ova in hor av alebo v bu n kvapaliny a materi ly v bl zkosti vykurovacieho telesa Je zak zan vykon va ak ko vek pravy na ohr...

Page 18: ...jte ho pomocou 5 ks skru tiek a podlo iek M5 10 Upozornenie Pre spr vne zatv ranie dver pridvihnite jednou rukou horn as s hor kom a a potom dotiahnite v etk ch 5 skrutiek Krok 3 Pripojte k hor ku had...

Page 19: ...imo otvoren plame alebo in zdroj zap lenia Presn pokyny na pou itie plynovej f a e z skate od svojho dod vate a plynu Plynov f a a mus by v dy pou van prepravuje aj skladovan vo zvislej polohe Pred pr...

Page 20: ...hor kom na svojom mieste Re pektujte minim lnej vzdialenosti od hor a v ch materi lov SK KA TESNOSTI Nikdy nepou vajte ohe pri sk ke tesnosti Nikdy nefaj ite pri sk ke tesnosti Plynov pr pojky pr str...

Page 21: ...duchov ho otvoru Na vstupuje na pripojenie k ventilu opatren prevle nou maticou W 21 8 x 1 14 L a na v stupe hadicovou koncovkou pre hadicu na PB s vn tornou svetlos ou 8mm alebo z vitom G 1 4 L Techn...

Page 22: ...he PILOT nechajte odvzdu ni aspo 2 min ty alebo k m nepoc tite plyn Mal tlak plynu Plynov f a a je pr zdna Vynech vania zapalovania Pre zap lenie pou ite z palky Hor k zhas na Ne istoty okolo PILOT ho...

Page 23: ...P 37 I3P 50 Ve kos trysky 1 64mm 1 64mm 1 55m 1 64mm 1 60mm Tepeln v kon 11kW 11kW 13 5kW 11kW 12 5kW Spotreba plynu 0 8kg h 0 8kg h 0 9kg h 0 8kg h 0 9kg h Model H1109B V robca Ningbo Innopower Hengd...

Page 24: ...V robok je v s lad s n ie uveden mi predpismi Smernica Eur pskeho parlamentu a Rady 2016 426 ES a normami EN 14543 2005 A1 2007 Certifik t 0063CO7365 V robca Ningbo Innopower Hengda Metal Products Co...

Reviews: