Section 5, Page 12
01/2001, CATTRON
- THEIMEG
TM
Frequency Bank entry and report (PSEZ and CS Controllers)
, continued.
3. Press and release button #2. The controller will emit one long ‘beep’ followed by two short
‘beeps’
and the green LED will flash rhythmically with each short ‘beep’. This indicates you
are now in the Frequency Bank Data Entry and Report Mode.
4. To find the present Frequency Bank value, press and release button #4. The unit will emit
one long beep to alert you, then will beep out the Frequency Bank setting count with short
beeps. (i.e., zero beeps for frequency table USA 1, two beeps for frequency table USA 3 –
see Table 5-1 below). The green LED will also flash with each short beep/count. (‘0’ is
represented by a long beep with no LED flash). Look, listen, and count to determine the
existing value. Repeat as necessary by pressing button #4.
5. To increment the Frequency Bank, press and release button #2 (Frequency Bank). Each
depression will increment the Frequency Bank by one, continuing from its present value until
it reaches 4, then will roll over to zero and start again. (The unit will beep each time button
#2 is depressed). See Table 5-1 below for frequency bank assignment.
6. Press button #4 to confirm your desired setting.
7. Once you have entered the desired Frequency Bank, set the ON/OFF switch on the PS
controller to ‘OFF’ to permanently store the Frequency Bank.
Frequency entry and report (PSEZ and CS Controllers).
1. Referring to Figure 5-1 above, set the ON/OFF switch on the PS controller to ‘OFF’. Make
sure the red STOP Switch on the controller is unlatched and set to the ‘RUN’ (pulled up)
position.
NOTE: Provided a Frequency and Address has been programmed in the controller,
applying power to the controller with the red STOP Switch set to ‘STOP’
(pushed down) will immediately place the Controller in a STOP message
transmit cycle. If a Frequency and Address has not been pre-programmed in the
controller, the STOP message transmit cycle cannot be sent. Instead, the
controller will emit three long beeps and reset.
2. Press and hold down buttons #1 and #2 (see figure 5-1 above) and set ON/OFF switch to
‘ON’. Pause approximately for one second or until the green LED illuminates, then release
buttons #1 and #2. The controller will emit one long ‘beep’, which means you are now in the
Main Menu
of the address and frequency program.
NOTE: The yellow LED will flash instead of the green LED when low battery voltage is
detected.
Summary of Contents for i-Key
Page 2: ......
Page 14: ...Page xii 01 2001 CATTRON THEIMEG TM EZ CS AT Rx Rx Tx Tx Tx Rx Rx Rx ...
Page 20: ...Section 1 Page 6 01 2001 CATTRON THEIMEG TM This page intentionally left blank ...
Page 44: ...Section 4 Page 4 01 2001 CATTRON THEIMEG TM ...
Page 52: ...Section 4 Page 12 01 2001 CATTRON THEIMEG TM This page intentionally left blank ...
Page 68: ...Section 5 Page 16 01 2001 CATTRON THEIMEG TM This page intentionally left blank ...
Page 75: ... 01 2001 CATTRON THEIMEG TM Section 6 Page 7 Item 7 Carrying strap shoulder Part 42C 0057 ...
Page 89: ......