INSTALLATION GUIDE
21
Rev. 0/ 14-07-2020
PT
Tariff program
identification
2 full digits and 3
decimal places
Indication by icon of
the current tariff
range (F1,F2,F3)
T1
Totalizer band 1
5 full digits and 3
decimals
ft
3
T2
Totalizer band 2
5 full digits and 3
decimals
ft
3
T3
Totalizer band 3
5 full digits and 3
decimals
ft
3
TA
Totalizer of
volumes in alarm
5 full digits and 3
decimals
ft
3
SD
Device status
1 whole digit
0 = normal
1 = not
configured 2 =
maintenance
SV
Status of the shut-
off valve
2 full digits
00 = valve
open 20 =
valve closed 40
= enabled for
reopening
If in state 40 the
enter pressure
causes the
valve to open
DG
Diagnostics
2 full digits for error
coding
1 integer digit for error
status
0: not active
1: active
Empty screen:
no error
present.
Compiled screen:
Switching to the
next error encoding
via enter
E.g. 05: 1 => error
coding 05 active
T H
Volume
totaliser
(previous
period)
5 full digits and 3
decimals
ft
3
T1 H
Totalizer band 1
(previous period)
5 full digits and 3
decimals
ft
3
T2 H
Totalizer band
2 (previous
period)
5 full digits and 3
decimals
ft
3
T3 H
Totalizer band
3 (previous
period)
5 full digits and 3
decimals
ft
3
TA H
Totalizer of
volumes in alarm
5 full digits and 3
decimals
ft
3