Installation Guide 

and Users Manual

Wall Mount Range Hood

IMPORTANT:

Read and save these instructions.

NOTICE:

Installer:

 Leave this guide with the homeowner

Homeowner:

 Keep this guide for future reference

218 Series Pro Wall Hood

Rev. 1025u.1d

 

Summary of Contents for 218 Series

Page 1: ... and Users Manual Wall Mount Range Hood IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference 218 Series Pro Wall Hood Rev 1025u 1d ...

Page 2: ...e authorities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Ducted fans MUST always be vent...

Page 3: ...go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a Class A B C extinguisher and you already know how to operate it The fire is small and contained in the area where it is started The fire department is being...

Page 4: ... 10 11 Installation overview 11 USE AND CARE Range hood operations diagrams 12 16 Troubleshooting 17 Use and care information 18 Specifications 18 MAINTENANCE Cleaning 19 Replacing the filter light bulb 19 WARRANTY Coverage exceptions 20 Disclaimer contact us 21 Tools needed Page 3 Level Flat blade and Philips screw drivers Powered screwdriver or drill Measuring tape Utility knife Marker or pencil...

Page 5: ...p Range Hood vary with model Optional Duct Tube For sheet rock only Parts supplied Lower standard chimney Upper standard chimney Mounting Bracket Grease Tunnel Baffle Filters Page 4 Ducting Transition Baffle Filter Spacer ...

Page 6: ...s recommended between stove top and the bottom of range hood It is recommended that the range hood be vented vertically through the roof through 8 20 3 cm or bigger round metal aluminum vent work The size of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used DO NOT install two elbow...

Page 7: ...ould be no higher than 31 inch It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to stove top manufacturer s height clearance requirements and recommended hood mounting height above range Due to di...

Page 8: ...r terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use metal aluminum duct work only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Use caulking to seal exterior wall or roof opening around the cap Vertical roof venting Roof cap Option 2 Side wall cap Horizontal...

Page 9: ... or ground circuit IMPORTANT Save Installation Instructions for electrical inspector s use The range hood must be connected with copper wire plug only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable A U L or C S A listed strain relief must be provided at each end of the power supply cable Wire...

Page 10: ...ings for power supply cable and vent see Venting Methods and Electrical requirements Pages 7 8 If venting to the outside install vent system see 5 Venting Requirements Page 5 Use caulking to seal exte rior wall or roof openings Disconnect main electrical supply prepare and run electrical wiring through ceiling or wall Leave approxi 6 mately 12 of electrical cord hanging from the ceiling Do not res...

Page 11: ...or best weight support Concrete wall Use designated screws not provided Wood wall Use at least 5 cm long wood screws not provided Fasten two Type A anchors for range hood and for mounting bracket or air diverter on the wall as shown 6 in Figure 4 Loosely fasten two Type B screws onto anchors DO NOT fasten screws all the way Hang the range hood on the Type B screws and hand tighten them Leave appro...

Page 12: ... to the range hood and the upper end to the vent system Make sure the main electri cal supply remains disconnected then connect power plug to the electrical cord or wall plug Have one person carefully position both upper and lower chimneys on the range hood let the second person 9 slide the sides of the chimneys into the 1 8 gap Fasten both chimneys with four Type C screws Install grease tunnel an...

Page 13: ... Delay Digital Timer Indicates the length of time left for delay off function Power Off Delay Timer Indicator Lights up when auto shutdown delay timer function is on Controls Automatic cleaning reminder This range hood is equipped with a cleaning reminder that will activate following 30 hours of use When blower motor starts to rotate cumulative running time will be shown in Power On Elapsed Digita...

Page 14: ...lower motor is running press and hold Power button for over 3 seconds to activate delay off timer Power off delay indicator will lit up and power off delay digital timer will begin to countdown when it reaches zero the blower motor will shut down Adjusting the light Press Light button once to turn on the lights and once again to turn off the lights While the lights are off press and hold Light but...

Page 15: ...Page 14 Control type 1 Touch Sensitive Version Six speed with type GU10 bulb Measurements Diagrams 12V 75W Transformer Control type 1 Touch Sensitive Version Six speed with type MR16 bulb ...

Page 16: ...Page 15 Measurements Diagrams Continued Control type 1 Soft Touch Version Six speed with type GU10 bulb Control type 1 Soft Touch Version Six speed with type MR16 bulb 12V 75W Transformer ...

Page 17: ...Page 16 Measurements Diagrams Continued All measurements in parenthesis are in millimeter All inch measurements are converted from millimeters thus inch measurements are estimated ...

Page 18: ...iently with insufficient duct size For example 10 25 4 cm duct over 8 20 cm hole and loosely secured Check if duct is clogged or if damper unit is not opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at 4 all is stuck or is rattling The blower might be jammed or scraping the bot tom due to shipping dam...

Page 19: ...OTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BECAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACU ATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN you may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguish er ONLY if You know you have a Class ABC extinguis...

Page 20: ... hood DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after ex posure and wipe dry with a clean cloth Cleaning Stainless...

Page 21: ...nsumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Damage of product caused by accident fire floods or act of God The manufacturer and or distributor reseller is no...

Page 22: ...of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchang es Service visits not covered under warranty will carry a servi...