7.0 WINTERIZATION
The power unit should be winterized if stored at temperatures below 32
degrees Fahrenheit (0 degrees Celsius).
Total system displacement with 100 ft of hose (optional):
4.3
gallons. Total system displacement without hose:
2.0
gallons.
To winterize the CaviBlaster
®
1325-D power unit:
Fill a 5 gallon or larger tank with appropriate antifreeze solution.
Insert a feed pump into the antifreeze tank.
Start the unit and make sure the pump is primed.
Attach a minimal amount of pressure hose and direct the outlet of the hose into the antifreeze
tank.
Run the unit without gun attached until antifreeze comes out of the end of the hose for 10
seconds.
Stop the unit.
Following this procedure will ensure that all the critical system components
exposed to water have been flushed with antifreeze.
This space intentionally left blank
(EOS)
Page - 38
CaviBlaster 1325-D Operations Manual
For More information please email sales@cavidyne.com or call 1-(352)275-5319