WARNING

 

 

 

While  the  CaviBlaster

TM

  system  is  very  safe,  operators  should  exercise  care  when  using  the  equipment. 

The cavitation “flame” can be safely passed over the operators’ skin at normal operating distances of 2” - 

3” (5 - 8 cm) from the tip of the nozzle. However, at very close distances (typically less than 1”) both 

nozzles  are  capable  of  causing  harm  to  the  operator, particularly  in  the  initial  instant  that  the  system  is 

activated.  For  that  reason,

  operators  should  exercise  caution  when  operating  the  Zero  Thrust  Gun 

with the nozzles in close proximity to the body. The operators should also ensure that the reverse-

thrust nozzle guard is secured in the correct position prior to operating the Zero Thrust Gun.

 

 

The  operators  of  the  CaviBlaster

TM

  system  should  always  wear  neoprene  or  heavy  rubber  gloves

  to 

provide protection to the hands and, in particular, to the nails. The gloves will absorb most of the energy 

produced by bursting cavitation bubbles and prevent the cavitation bubbles from contacting the operators’ 

hands.  The  gloves  will  also  protect  operators’  hands  from  the  initial  shockwave  when  the  Zero  Thrust 

Gun is activated.

  

 

Serious  harm  and  injury  may  result  from  the  misuse  of  CaviBlaster

TM

  system  equipment  or 

improperly  selected  fittings,  hoses  or  attachments. 

All  components  of  the  system  should  be  checked 

against the  manufacturers’ instructions to ensure that they are compatible with the pressures being used 

and  of  the  correct  thread  type  and  pressure  rating  for  the  intended  service.  Refer  to  these  Operating 

Instructions and to the motor and pressure pump manufacturers’ operation manuals for instructions or call 

CaviDyne, LLC at (352) 275-5319 with any questions. 

 

CAUTION:  

DO  NOT  USE  THIS  EQUIPMENT  TO  CLEAN 
SENSITIVE 

SURFACES 

as 

LED-Lights, 

Underwater Lights, Elecronic Equipment, Etc. 

 

Summary of Contents for Caviblaster 1222-E50

Page 1: ...Model 1222 E50 Operation Maintenance Manual www cavidyne com ...

Page 2: ... on pump Figure 3 per manufacturer s operating manual Figure 1 Figure 2 Figure 3 5 To supply water to the CaviBlasterTM power unit connect a 1 25 mm diameter feed hose to the cam lock plug on the inline strainer inlet Figure 4 Either fresh water or seawater can be used with this system The water source must supply the CaviBlasterTM with water at a volume of greater than 12 gallons 45 liters per mi...

Page 3: ...s primed turn off the water supply to the system Figure 6 4 Connect the 13 mm high pressure hose to the quick connect plug under the pressure regulating unloader Figure 6 The high pressure hose has a brass quick connect socket on the end The 1222 E CaviBlasterTM can deliver the required pressure utilizing up to 300 feet 100 meters of diameter rubber hose or 600 feet 200 meters of thermoplastic hos...

Page 4: ...he green START button on the motor controller Figure 8 mounted on top of the motor to start the motor 10 The system is now ready to operate refer to photo on cover for overall system set up Figure 8 Figure 9 WARNING Although the CaviBlasterTM system is safe to use when submerged in water the system generates a high pressure up to 2 200 psi water stream which can cause injury when the Zero Thrust G...

Page 5: ... the operating instructions when the replacement diver is ready to continue cleaning 6 Ensure that the Zero Thrust Gun is submerged any time the motor and pressure pump are operating Adjusting the CaviBlasterTM system for maximum performance 1 If using a calibration pressure gauge situated between the pressure hose and the CaviBlasterTM Zero Thrust Gun the water pressure should be 2 200 psi with t...

Page 6: ...ge close the pressure regulating unloader until there is just a trickle of water less than gallon or 1 liter per minute coming out of the bypass with the Zero Thrust Gun trigger in the open or ON position Shutting down the CaviBlasterTM power unit 1 Stop the motor by depressing the red STOP button Figure 8 on the motor controller 2 Shut off the supply of water to the pump 3 Squeeze the Zero Thrust...

Page 7: ...plug 4 Attach the pressure hose and Zero Thrust Gun 5 Connect the power cable to the power source 6 Make sure that the diver is ready to work and that the Zero Thrust Gun is submerged in the water Apply hearing protection if the diver is not wearing a helmet 7 Start the motor 8 Activate the cleaning cavitation stream by squeezing the Zero Thrust Gun trigger to open or ON 9 Proceed with cleaning 10...

Page 8: ...lways wear neoprene or heavy rubber gloves to provide protection to the hands and in particular to the nails The gloves will absorb most of the energy produced by bursting cavitation bubbles and prevent the cavitation bubbles from contacting the operators hands The gloves will also protect operators hands from the initial shockwave when the Zero Thrust Gun is activated Serious harm and injury may ...

Reviews: