Page 17/43
For more information please email sales@cavidyne.com or call 1-(352)275-5319
4.3 Initial Set Up
After first receiving the CaviBlaster
®
power unit, the following must be checked
and completed:
1) Connect the battery (See Section 4.3.1).
2) Add engine oil (See Engine Manual located in the
APPENDIX
).
3) Add engine coolant (See Engine Manual located in the
APPENDIX
).
4) Add pump oil (See Pump Manual located in the
APPENDIX
).
5) Connect the feed or suction (clear) hose (See Section 4.3.2 and Figure
2.3).
6) Connect the bypass (red) hose (See Figure 2.3).
7) Connect the pressure hose (See Figure 2.3).
8) Connect the electric feed pump (See Section 4.3.2 and Figure 2.3).
9) Fill the fuel tank using diesel fuel ASTM Grade 1-D or 2-D, or EN 590.
(See fuel requirements in Engine Manual located in the
APPENDIX
).
4.3.1 Connecting the Battery Terminals
For shipping purposes, the battery terminals have been disconnected. To
reconnect the battery, reference Figure 4.3 and the procedure below:
1. Remove the engine ignition key. (See Figure 2.3)
2. Open the battery box by loosening the strap and removing the cover.
3. Connect the battery terminals as follows:
RED
to positive terminal
BLACK to negative terminal
4. Tighten the terminal screws securely.
5. Replace the battery cover and secure with strap.
Engine and/or pump fluids may have been removed
for shipment. Check fluid levels prior to starting.