To use the feed pump supplied with the system:
•
Turn the engine ignition key to OFF (See Figure 2.3).
•
Connect the cam-lock socket on the 1-1/2
” clear PVC feed hose to the
water inlet connection on the control panel (See Figure 2.3).
•
Connect the electrical plug on the feed pump power cable to the
matching receptacle on the control panel (See Figure 2.3).
•
Submerse the feed pump into the water source. How high????
•
Pull the feed pump ON/OFF switch out to activate the feed pump (See
Figure 2.3).
•
Run the feed pump until water begins to flow from the pressure hose
connection on the control panel.
•
Turn off the feed pump.
•
Release the Emergency Engine Shut-Down button
•
It is important not to operate the feed pump for long periods of time
without the engine operating as this will discharge the battery.
To use force feed from an alternate source:
•
Turn the engine ignition key to OFF (See Figure 2.3).
•
When feeding the CaviBlaster
®
with an alternate water source,
the
source must supply water at a volume of greater than 28 GPM (106
LPM) at a maximum pressure of 70-psi (4.8 BAR).
•
Connect a 1-1/2
” cam-lock socket on the water supply hose to the
water inlet connection on the control panel (See Figure 2.3).
•
Turn on the alternate water source until water begins to flow from the
pressure hose connection on the control panel. (See Figure 2.3).
•
Turn off the alternate water source.
Ensure that the feed hose is connected to the inlet
connection and the water supply is on prior to starting the
pressure pump. Failure to supply water to the pressure
pump will cause damage to the pressure pump.
To use gravity feed:
•
Locate the water supply tank so that the bottom of the tank is higher
than the water inlet on the control panel (See Figures 2.3 and 4.4).
•
Turn the engine ignition key to OFF (See Figure 2.3).