Page 21/43
For more information please email sales@cavidyne.com or call 1-(352)275-5319
•
Connect a minimum 1-1/2
” hose to the water inlet 1-1/2” cam-lock plug.
•
Connect the other end of the hose to the water supply tank.
•
Make sure the lowest point in the hose line is the connection with the
power unit.
•
Turn on the gravity feed water source until water begins to flow from
the pressure hose connection on the control panel. (See Figure 2.3).
•
Turn off the gravity feed water source.
•
It is essential that adequate water is supplied to the water supply tank
to maintain the water level several inches above the bottom of the
tank. Failure to maintain an adequate water level in the supply tank
could starve the pressure pump of water causing damage to the seals
or other components of the pressure pump.
Ensure that the water source can reliably deliver the maximum pressure pump
flow of 28 GPM (106 LPM). A minimum flow of 35 GPM (133 LPM) is
recommended to ensure that the pressure pump is not starved of water. If
connecting to a tank, locate the bottom of the tank above the water inlet
connection on the power unit to ensure a flooded suction line (See Figure 4.4).
This space intentionally left blank
(EOS)