Page 26/43
For more information please email sales@cavidyne.com or call 1-(352)275-5319
Figure 5.1
– Engine Emergency Shut-Down and Throttle Control
5.4. Adjusting the CaviBlaster
®
for maximum performance
The pressure at the nozzle of the zero-thrust gun has to be maintained within
certain limits to achieve cavitation and for best performance results. If using a
calibration pressure gauge situated between the pressure hose and the
CaviBlaster
®
gun, the water pressure should be 2,800-psi (193 BAR) with the
gun submerged and the gun
trigger in the open or “ON” position. For best results,
repeat this calibration procedure if cleaning performance degrades, or every 3
months at a maximum.
To calibrate the pressure at the zero-thrust gun, follow the procedure below:
- Stop the power unit and pull the gun trigger to discharge any residual
pressure in the hose lines.
- Disconnect the gun/DoubleDome with its whip hose from the main hose line.
A CALIBRATION TEST GAUGE IS RECOMMENDED
WITH EVERY UNIT. CONNECT BETWEAN THE END
OF THE PRESSURE HOSE AND THE WHIP HOSE OR
GUN.
Engine ignition key
Throttle cable knob.
Push on the red knob to
release and shut down
the engine. Pull the
cable all the way out
and twist to lock for full
throttle.