7–RoCE Configuration
Configuring RoCE on the Adapter for Windows Server
139
AH0054602-00 J
3.
Select one of the following counter types:
Cavium FastLinQ Congestion Control
:
Increment when there is congestion in the network and ECN is
enabled on the switch.
Describe RoCE v2 ECN Marked Packets and Congestion
Notification Packets (CNPs) sent and received successfully.
Apply only to RoCE v2.
Cavium FastLinQ Port Counters
:
Increment when there is congestion in the network.
Pause counters increment when flow control or global pause is
configured and there is a congestion in the network.
PFC counters increment when priority flow control is configured
and there is a congestion in the network.
Cavium FastLinQ RDMA Error Counters
:
Increment if any error occurs in transport operations.
For details, see
4.
Under
Instances of selected object
, select
Total
, and then click
Add
.
NOTE
If Cavium RDMA counters are not listed in the Performance Monitor
Add Counters dialog box, manually add them by issuing the following
command from the driver location:
Lodctr /M:qend.man