9–iSER Configuration
Configuring iSER for SLES 12
183
AH0054602-00 J
Figure 9-4. Checking for New iSCSI Device
Configuring iSER for SLES 12
Because the targetcli is not inbox on SLES 12.
x
, you must complete the following
procedure.
To configure iSER for SLES 12:
1.
To install targetcli, copy and install the following RPMs from the ISO image
(x86_64 and noarch location):
lio-utils-4.1-14.6.x86_64.rpm
python-configobj-4.7.2-18.10.noarch.rpm
python-PrettyTable-0.7.2-8.5.noarch.rpm
python-configshell-1.5-1.44.noarch.rpm
python-pyparsing-2.0.1-4.10.noarch.rpm
python-netifaces-0.8-6.55.x86_64.rpm
python-rtslib-2.2-6.6.noarch.rpm
python-urwid-1.1.1-6.144.x86_64.rpm
targetcli-2.1-3.8.x86_64.rpm
2.
Before starting the targetcli, load all RoCE device drivers and iSER modules
as follows:
#
modprobe qed
#
modprobe qede
#
modprobe qedr
#
modprobe ib_iser
(initiator)
#
modprobe ib_isert
(target)
3.
Before configuring iSER targets, configure NIC interfaces and run L2 and
RoCE traffic, as described in
on
.