7–VMware Driver Software
FCoE Support
70
83840-546-00 N
Verifying Installation
To verify the correct installation of the driver and to ensure that the host port is
seen by the switch, follow these steps.
To verify the correct installation of the driver:
1.
To verify that the host port shows up in the switch fabric login (FLOGI)
database, issue the appropriate command:
For a Cisco
®
FCF:
show flogi database
For a a Brocade
®
FCF:
fcoe -loginshow
2.
If the host WWPN does not appear in the FLOGI database, provide driver
log messages for review.
Limitations
The following VMware driver software limitations exist:
NPIV is not currently supported with this release on ESXi, due to lack of
supporting inbox components.
Non-offload FCoE is not supported with offload-capable Cavium devices.
Only the full hardware offload path is supported.
Supported Distributions
The FCoE and DCB feature set is supported on VMware ESXi 5.5 and later.