9–Configuring iSCSI Protocol
iSCSI Offload in Windows Server
123
83840-546-00 N
3
Error
Maximum command sequence number is not serially greater
than expected command sequence number in login response.
Dump data contains Expected Command Sequence number fol
-
lowed by Maximum Command Sequence number.
4
Error
MaxBurstLength is not serially greater than FirstBurst
-
Length. Dump data contains FirstBurstLength followed by
MaxBurstLength.
5
Error
Failed to setup initiator portal. Error status is given
in the dump data.
6
Error
The initiator could not allocate resources for an iSCSI
connection
7
Error
The initiator could not send an iSCSI PDU. Error status
is given in the dump data.
8
Error
Target or discovery service did not respond in time for
an iSCSI request sent by the initiator. iSCSI Function
code is given in the dump data.
9
Error
Target did not respond in time for a SCSI request. The
CDB is given in the dump data.
10
Error
Login request failed. The login response packet is given
in the dump data.
11
Error
Target returned an invalid login response packet. The
login response packet is given in the dump data.
12
Error
Target provided invalid data for login redirect. Dump
data contains the data returned by the target.
13
Error
Target offered an unknown AuthMethod. Dump data contains
the data returned by the target.
14
Error
Target offered an unknown digest algorithm for CHAP.
Dump data contains the data returned by the target.
15
Error
CHAP challenge given by the target contains invalid
characters. Dump data contains the challenge given.
16
Error
An invalid key was received during CHAP negotiation. The
key=value pair is given in the dump data.
17
Error
CHAP Response given by the target did not match the
expected one. Dump data contains the CHAP response.
Table 9-5. Offload iSCSI (OIS) Driver Event Log Messages (Continued)
Message
Number
Severity
Message