9–Configuring iSCSI Protocol
iSCSI Offload in Windows Server
113
83840-546-00 N
Installing the Microsoft iSCSI Initiator
Configuring Microsoft Initiator to Use Cavium’s iSCSI Offload
Installing Cavium Drivers
Install the Windows drivers as described in
Chapter 4 Windows Driver Software
Enabling and Disabling iSCSI-Offload
For Windows operating systems, use CCM pre-boot utility or the server pre-boot
UEFI HII device configuration page to configure the DCB parameters for lossless
iSCSI-TLV over DCB mode.
Use the QCC GUI, QCS CLI, or the QCC PowerKit to enable or disable the
iSCSI-Offload instance per port on Windows in single function mode. To configure
iSCSI-Offload in NPAR mode, use the NPAR configuration page in any of the
following applications:
QCC GUI
QCS CLI
QCC PowerKit
Pre-boot server UEFI HII
Pre-boot server CCM
To enable or disable iSCSI-Offload using the QCC GUI:
1.
Open QCC GUI.
2.
In the tree pane on the left, under the port node, select the port’s virtual bus
device instance.
3.
In the configuration pane on the right, click the
Resource Config
tab.
4.
Complete the Resource Config page for each selected port (
) as
follows:
a.
To enable iSCSI-Offload for that port, for the
iSCSI
parameter, select
the
Value
check box.
b.
Or, to disable iSCSI-Offload for that port, for the
iSCSI
parameter, clear
the
Value
check box.