13.

 MAINTENANCE & TROUBLE SHOOTING:

The smoke alarm should be vacuum cleaned 

once per quarter, to remove dust particles, and 

it can be wiped with a damp cloth. (Do not open 

the alarm). 

NOTE: You can easily vacuum clean the smoke 

chamber through the dedicated openings in the 

top cover, and it’s possible to test the alarms by 

pressing the cover at the same time.

High humidity condensing which can be resolved 

by drying the smoke alarm.

If the smoke alarm does not work when the test 

button is pushed, the probable cause is a power 

failure. Always test the alarm after replacement 

of battery.

If the problem continues, please visit www.cavius.com 

for any trouble shooting. 

Only the alarm with the low battery will sound, 

no other connected alarms will sound. It is safe 

to change batteries in the alarms without going 

through the learn process again – they will not for-

get the codes during the battery change process. 

12.

 BATTERY REPLACEMENT:

To replace the battery, detach the smoke alarm 

from the power supply by twisting counterclock-

wise. 
Remove the plastic cover to access the battery.

Replace the battery respecting the polarities. 

Attach the alarm on power supply by twisting 

clockwise until it clicks, and test the alarm.

14. 

OTHER INFORMATION:

Do not paint the alarm.

Disposal: For battery and product, please dispose 

properly at the end of life. This is electronic waste 

which should be recycled.

WARNING: Please remove dust cover after 

installation. Smoke will not be able to reach the 

chamber while dust cover is in place.

The CE mark affixed to this product confirms its 

compliance with the European Directives which 

apply to the product and, in particular, its compli-

ance with the harmonized specifications of stan-

dard EN 14604 relating to Construction Products 

Regulation 305/2011.

All Rights reserved: CAVIUS Aps assumes no respon-

sibility for any errors, which may appear in this manual. 

Further more, CAVIUS Aps reserves the right to alter the 

hardware, software, and/or specifications detailed herein at 

any time without notice, and CAVIUS Aps does not make 

any commitment to update the information contained 

herein. All the trademarks listed herein are owned by 

their respective owners. Copyright © CAVIUS Aps.

0333

17

Download DoP document: www.cavius.com

EN 14604:2005 + AC :2008

DoP no.: 2201-003

126979 rev1

Developed by CAVIUS Aps Julsøvej 16, DK-8600  

Manufactured in P.R.C.

4

Summary of Contents for 2201-003

Page 1: ...garages laundries or too close to fireplaces areas where either dampness gases or smoke could occur Place the alarm where it is reachable in order to test the alarm and for maintenance 4 PLACEMENT The smoke alarm is designed to be installed on a ceiling With a minimum of one smoke alarm per floor and a maximum distance between smoke alarms of 10 meters For ceiling installation The smoke alarm shou...

Page 2: ...d OFF Remove the plastic cover to access to the power supply connector Pass the lamp wire through the smoke alarm 5 INSTALLING THE SMOKE ALARM NOTE THIS ALARM NEEDS TO BE INSTALLED BY A PROFESSIONAL MAKE SURE ELECTRICITY IS SWITCHED OFF BEFORE STARTING THE INSTALLATION CAUTION LIVE NEUTRAL AND EARTH MUST BE CORRECTLY INSTALLEDAND NOT MIXED UP NOTE The alarm is delivered in the packaging with a dus...

Page 3: ...d 8 ALARM MODE When the smoke is detected the smoke alarm will go into Alarm Mode It will sound the alarm signal and the red LED will flash The smoke alarm will also transmit the alarm signal to the other connected alarms which will also sound the alarm signal after a short delay The CAVIUS Wireless Family have two different alarm signals Alarm signal 1 is life threatening alarms like a smoke alar...

Page 4: ...the battery respecting the polarities Attach the alarm on power supply by twisting clockwise until it clicks and test the alarm 14 OTHER INFORMATION Do not paint the alarm Disposal For battery and product please dispose properly at the end of life This is electronic waste which should be recycled WARNING Please remove dust cover after installation Smoke will not be able to reach the chamber while ...

Reviews: