background image

10

11

MARK UP 

SCREW HOLES 

WITH A PEN

5. Installation of heat alarm:
Info:
 The label on the product must 

not be removed due to  

important information.

Option 1 – Standard base 
1.
 Use the mounting 

  base ring to mark the  

  screw holes on the ceiling.

 

USE THE 

ENCLOSED 

SCREWS AND 

PLUGS FOR 

INSTALLATION

CLICK THE HEAT 

ALARM FIRMLY INTO  

THE BASE TO ACTIVATE

Summary of Contents for 3104-001

Page 1: ...PLEASE READ THIS USER GUIDE CAREFULLY THERMAL HEAT ALARM THE WORLD S SMALLEST ...

Page 2: ...________________________________________________ 16 Alarm mode_______________________________________________________________ 16 Hush function _____________________________________________________________ 17 Add extra device __________________________________________________________ 18 Low battery indicator ______________________________________________________ 19 Functional Information __________...

Page 3: ...that can be interconnected within a house group are 1000 Please note These must be alarms or devices from the CAVIUS Wireless Family range The distance between interconnected alarms depends on the house layout and they should always be tested after installation It is not advised to be more than 10m distance between two alarms Diameter 65mm Height 44mm 2 3 Alarm condition aural signal pattern accor...

Page 4: ... hallways and stairways Alarms in each room such as bedrooms and living rooms 2 Areas where NOT to install heat alarms Bedrooms Lounge Dining room Hallway Family room NOTE Thermal heat alarms are designed to be installed in areas where flaming fires occur over smouldering fires 4 5 ...

Page 5: ... risks may occur Never install directly above the oven hob stove 6 7 For kitchen installation CEILING MAXIMUM 100cm 4 How to set up and connect alarms All alarms that need to be connected in the house should be put into Link Mode by sliding the switch on the back of the alarm to the Link Mode position 2 LINK MODE 1 NORMAL MODE ...

Page 6: ...code to the other alarms take note of which alarm is the Master you may need this for adding extra devices in future The red LED will flash As the other alarms receive the specific house code they will also flash the LED light When all alarms flash the red LED they are connected and can be switched out of Link Mode and installed ...

Page 7: ...o The label on the product must not be removed due to important information Option 1 Standard base 1 Use the mounting base ring to mark the screw holes on the ceiling USE THE ENCLOSED SCREWS AND PLUGS FOR INSTALLATION CLICK THE HEAT ALARM FIRMLY INTO THE BASE TO ACTIVATE ...

Page 8: ...O THE BASE TO ACTIVATE Option 2 Recess Kit 1 Place the Cover Ring on the area where you wish to install the heat alarm trace around the inside of the ring 2 Using your hole saw 68mm 71mm cut a hole into the surface CAUTION Ensure there is no wiring or any electrical equipment behind the surface you are drilling your hole into HOLE SAW DRILL REQUIRED 68mm 71mm ...

Page 9: ... your finger during the testing to minimise the sound level emitted If any problems occur during testing visit www cavius co nz or www cavius com au for further trouble shooting 6 Test function After installation and at least once per quarter test all of your alarms to ensure they are operating correctly and are within range of each other It is recommended to check visually every week if the LED f...

Page 10: ...source of the alarm before using the hush function This is to make sure that it is not a life threatening situation 7 Normal mode In normal mode the LED will flash every 48 seconds to show the alarm is functioning 8 Alarm mode When a rapid and constant change of temperature is detected the heat alarm will go into Alarm Mode It will sound the alarm signal and the LED will flash Please note that onl...

Page 11: ... all devices by repeating the test function Section 7 after adding devices Low battery indicator Your product has a 5 year battery life When the battery is starting its end of life a short beep will sound out every 48 seconds for 30 days The alarm effected by the low battery will only beep no other connected alarms will sound It is safe to change batteries in the alarms without going through the l...

Page 12: ... 3187 NZ www cavius co nz for Australia CAVIUS Australia PTY Limited PO Box 6126 Yatala QLD 4207 Australia www cavius com au FUNCTIONAL INFORMATION Type of alarm CAVIUS heat alarm is a thermal heat alarm Alarm signal Fire alarm activation is indicated by a series of repeated tones The minimum sound level is 85 dB at 3 metres Battery Powered by one replaceable 3v CR123A 1600mAh lithium battery ...

Page 13: ...efective within the 10 year warranty CAVIUS APS Denmark will repair or replace the unit without charge and send back to the purchaser via the national Distributor at the Distributors cost The guarantee excludes labour costs freight costs service costs and any incidental and consequential damages Do not attempt to repair or service this product as this will invalidate the warranty Under some unusua...

Page 14: ...ed by batteries The limited warranty will not cover the battery life period indicated in the product sheet in these situations This warranty is in lieu of any other warranty either expressed or implied You can register your CAVIUS devices on our website 127482 rev2 www cavius co nz www cavius com au ...

Page 15: ...PLEASE READ THIS USER GUIDE CAREFULLY THERMAL HEAT ALARM THE WORLD S SMALLEST ...