background image

Call +44 (0)33 0380 1329 or visit 

lumi-plugin.com for more information

5 Year  

Warranty

5

50,000  

Hours

16V

CE Mark

Beam Angle 

is 60°

Fire Rated 

30/60/90

Dimmable

700  

Lumens

Driver  

Included

Developed by CAVIUS Aps for Sleep Safe Systems Limited

T/A Lumi-Plugin - Lindenmuth House, 37 Lindenmuth Way, Greenham Business Park, Newbury, Berkshire, RG19 6HW

Manufactured in P.R.C.

In normal mode the LED will flash every 48 seconds to show 

correct operation.
The green LED is on when the alarm is connected to mains power. 

It may take up to 1 minute to indicate that mains power has been 
connected. 

When the heat is detected, the heat alarm will go into ‘Alarm 

Mode’. It will sound the alarm signal and the red LED will flash. 
The heat alarm will also transmit the alarm signal to the other 

connected alarms, which will also sound the alarm signal after  

a short delay. 
The CAVIUS Wireless Family have two different alarm signals:
Alarm Signal 1 --- --- --- is a life threatening alarm, like a smoke 

alarm. 
Alarm Signal 2 - - - is a non-life-threatening alarm, like  

a flooding alarm: 
Smoke alarm signal: --- --- ---
Heat alarm signal: --- --- ---
Flood alarm signal: - - -
CO alarm low level signal: - - -
CO alarm high level signal: --- --- ---
Please note: Only the originating alarm’s red LED will flash,  

so it can be identified.

If the heat alarms are to set into a false alarm by cooking, 

fireplace, etc. they can be paused for 10 minutes by pressing the 

test button on the originating heat alarm only (indicated by the 

flashing LED).
The reason for this is that it is necessary to locate the source of 

the alarm before using the hush function. This is to make sure 

that it is  not a life threatening situation. 

Your product has a battery back-up with a 1 year life in battery 

mode without mains power, and up to 10 years normal life with 

mains. However, we recommend to replace the battery every 5 

years.
When the battery is starting its end of life, a short beep will 

sound out every 48 seconds for 30 days.

The heat alarm should be vacuum cleaned once per quarter, to 

remove dust particles, and it can be wiped with a damp cloth. 

(Do not open the alarm). 
Please note: You can easily vacuum clean the heat chamber 

through the dedicated openings in the top cover, and it’s possible  

to test the alarms by pressing the cover at the same time.
High humidity condensing which can be resolved by drying the  

heat alarm.
If the heat alarm does not work when the test button is pushed, 

the probable cause is a power failure. Always test the alarm after 

replacement of battery. 

•  This luminaire is guaranteed for a period of 5 years  

or 50,000 hours - depending which comes first.

•  The heat alarm is guaranteed for a period of 2 years.
•  The guarantee period is invalid if the product has been 

tampered with; if any of the product labels, manufacturing 

labels, rating labels or serial labels have been removed; or  

the product has not been installed in accordance with  

local wiring regulations.

•  If the product fails within the guaranteed period, Sleep Safe 

Systems Limited T/A Lumi-Plugin will replace the product free  

of charge but take no responsibility for installation, operation  

or maintenance costs. 

•  Lumi-Plugin reserves the right to change the product  

specification without notice.

Summary of Contents for LUMI-PLUGIN LP120

Page 1: ...lways be tested after installation It is not advised to install alarms with a separation of more than 10m The best areas to install the heat alarms Areas not suitable for smoke alarms due to high risk of false alarms Kitchen area Bathroom Garage or workshop Do not install the heat alarms In rooms where the temperature goes outside 10o C to 50o C Bedrooms Lounge Dining room Hallway Family room Inst...

Page 2: ...using magnets The alarm comes with a cable fitted Ensure the cable is coming out of the back of the luminaire and connect to the mains power 5 Lift both springs so they are in the upwards position then insert the luminaire into the 92mm cut out hole in the ceiling Make sure no cables are trapped under the springs and that the luminaire is centred in the hole Please note The alarm is delivered in t...

Page 3: ...uminaires Changing the heat alarm battery 1 Pull down the heat alarm so the magnets are not connected to the luminaire Diagram 5 2 Twist the heat alarm anti clockwise to release the alarm from the mains power 3 On the back of the alarm remove the cap over the battery Diagram 8 4 Remove the battery and replace with a new battery Diagram 9 Please note You will not be able to install the heat alarm w...

Page 4: ...o locate the source of the alarm before using the hush function This is to make sure that it is not a life threatening situation Low battery signal Your product has a battery back up with a 1 year life in battery mode without mains power and up to 10 years normal life with mains However we recommend to replace the battery every 5 years When the battery is starting its end of life a short beep will...

Reviews: