Below Sink Kit Components

1. 

Connect the included Inlet adapter (MC738) to the system housing’s 
labeled  Inlet  port.  Rotate  the  adapter  clockwise,  first  by  hand,  then 
using a wrench, to tighten onto the system.

2. 

Connect the included Outlet adapter (MC741) to the system housing’s 
labeled Outlet port. Rotate the adapter clockwise, first by hand, then 
using a wrench, to tighten onto the system.

Connect Tubing to the Outlet Port

1. 

Using wire cutters or a knife, cut 
(square cut) the tip end off of the 
blue plastic tubing (either connected 
to the faucet or a separate piece 
included with the Capacity Monitor). 
Do not use scissors.

2. 

Fully insert the tubing into the adapter 
on the OUTLET port of the system 
housing; the tubing should be inserted 5/8” into the adapter.

NOTE: When pushing the tubing into the adapter, you will encounter 
some resistance. This does not mean that the tube is fully inserted. 
Continue  to  push  firmly  until  the  tubing  is  inserted  as  far  as  possible 
(roughly 5/8” into the adapter).

3. 

Pull on the tubing to make sure that it is securely connected.

Connect Tubing to the Inlet Port

1. 

Using wire cutters or a knife, cut 
(square cut) the tip end off of the 
clear plastic tubing connected to the 
Adapta Valve. Do not use scissors. Do 
not cut more than 1/2” off of the end 
of the clear plastic tubing.

Connect the Tubing to the Housing

14

blue tubing

insert

OUTLET

adapter

INLET

adapter

clear tubing

insert

Summary of Contents for CB-As

Page 1: ...istance is required please contact your Dealer If Dealer is unavailable please contact CB Tech at 866 622 9373 Before You Begin Please read this manual before proceeding with the installation and use...

Page 2: ...umbers Below Sink Installation Below Sink Kit CBK1 Required 2 Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 The acrylic base Item 12 is an optional part available for purchase Part MC652 MC780 MC741 MC741 011...

Page 3: ...8 configuration 14 Adapta Valve 1 2 configuration threading adapter riser angle stop valve 14 water supply line with Adapta Valve in 3 8 configuration water supply line with Adapta Valve in 1 2 confi...

Page 4: ...your particular plumbing configuration requires fixtures different from those included with your shipment please contact your Dealer The following tools are recommended to install your DWS for below...

Page 5: ...he drilling location 3 If you have a porcelain ceramic or cast acrylic sink CAUTION Porcelain ceramic and cast acrylic surface materials are extremely hard and can easily crack or chip Use extreme cau...

Page 6: ...instructions for your faucet type 1 For a standard faucet proceed to section Installing the Standard Faucet Pg 6 2 For a capacity monitored faucet proceed to section Installing the Capacity Monitor Fa...

Page 7: ...7 cover plate countertop plastic washer wing nut large black washer lock washer blue tubing small black washer Complete Faucet Assembly with Blue Tubing MC652...

Page 8: ...city indicator plate tubing for housing countertop Capacity Monitor Assembly 1 3 6 7 9 4 5 12 13 8 2 14 5 15 15 11 10 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Faucets with Capacity Monitor Include Spout...

Page 9: ...ween the sink and the stud nut b Slide the hard plastic washer 11 upward over the blue tubing 5 black track washer 10 black wire 8 and faucet stud 4 c Slide the lock washer 12 upward over the faucet s...

Page 10: ...As OUTLET into the adapter 15 on the INLET 5 side of the FMU the tubing should typically be inserted 5 8 into the adapter The inlet side is the side from which the arrow points away on the capacity f...

Page 11: ...Reinsert the battery holder d Press and hold the check reset button on the FMU for six 6 seconds You should hear a long audio sound and the LED Display Plate will flash red and then green several tim...

Page 12: ...er Adapta Valve 3 8 configuration water supply line with Adapta Valve in 1 2 configuration 1 2 slip joint nut riser angle stop valve 3 8 slip joint nut Water supply line before installation Adapta Val...

Page 13: ...supply line and slip joint nut detach from either the angle stop valve or the faucet pipe 5 Connect the Adapta Valve to the pipe from which you removed the slip joint nut a Align the Adapta Valve to...

Page 14: ...ot use scissors 2 Fully insert the tubing into the adapter on the OUTLET port of the system housing the tubing should be inserted 5 8 into the adapter NOTE When pushing the tubing into the adapter you...

Page 15: ...1 Attach the metal bands to the mounting bracket a Using a slotted flat blade screwdriver loosen the connector screw on each of the two metal bands so that the slotted side of the bands separate from...

Page 16: ...bracket to the wall ensuring it is oriented in an upright position The bracket is in an upright position when the larger holes on each flat mounting plate on the sides of the bracket are at the botto...

Page 17: ...on the acrylic base with the ports and tubing facing down so that the tubing can feed through the openings at the side of the acrylic base 2 Diverter valve Used to connect the dual hose from the CB A...

Page 18: ...any faucets with an outside thread the diverter valve can attach directly to the faucet If the diverter valve is too small to attach to the faucet attach the inside thread female connector adapter par...

Page 19: ...t your Dealer to request part MC105 part MC109 or part MC719 as possible adapter solutions NOTE When connected properly the hose from the diverter valve should lead toward the back of the faucet and s...

Page 20: ...iv Adjust the Angle Stop Valve or water shutoff valve so that the water flow to the drinking water faucet does not exceed the flow rate NOTE It takes approximately 15 seconds to fill a quart at 1 0 g...

Page 21: ...e including without limitation the implied warranties of merchantability and fitness for a particular purpose to any person This limited warranted may not be altered varied or extended except by a wri...

Page 22: ...buttons on the diverter valve several times to lubricate it thoroughly 4 Reconnect the diverter valve to the faucet Dissolving requires vinegar may cause discoloration to the metal 1 Unscrew the dive...

Page 23: ...Notes...

Page 24: ...600 60 6046 1116 7251 Cathedral Rock Drive Las Vegas NV 89128 866 622 9373 www CarbonBlockTech com...

Reviews: