WARNING:
the installation date of the gas detector on the label and apply the label to
the frame as per figure " ".
Write
B
Each detector is tested and calibrated with the gas in question; the sensor life is 10 years,
but it may be reduced by pollution. After this
the device must be replaced.
time
Built-in
(figure )
fixing
B
59.5 mm
102 mm
(example)
EN
Replace
Every 10 years
................-.................
may 2027
DETECTOR ONLY
POSITIONING FOR USE AS AN LPG
The configuration bridge (see figure “A”) must be set
to “position ”.
B
The detector must be placed 20-40 cm from the floor
to obtain
effective intervention in the presence of
gas.
an
POSITIONING FOR USE AS A LPG AND
The configuration bridge (see figure “A”) must be set
to “position ”.
A
SOPORIFIC GAS DETECTOR
The detector must be located near the breathing area
of the occupants.
With this setting, the device has a higher sensitivity
and is able to detect
the presence of LPG. If the
detector is positioned at a height greater than 1.2m, it
is advisable to install a second dedicated device to
detect LPG only.
also
INSTALLATION
The installation can be built-in (see figure “B”) or with the spacer (see figure “C”). The detector can be combined with
the “Modular Plates Berker” series.
Configuration bridge (figure A)
Wall-fixing with spacer
C
(figure )
Position “A”
(
or set on the right)
select
Position “B”
( lector set on the left)
se
B
A
B
A