The device is supplied with power cables that are
about 50 cm long.
CONNECTIONS
Please respect the power supply voltage (12V
),
the polarity (black = negative, red = positive) and
connect the device to a line protected by a “3A” fuse
using cables with a suitable cross-section (minimum
,
INSTALLATION AND CONNECTIONS
cross-section 1mm²).
In the event of an alarm, on the white wire there is an
output signal (+12V - max 250mA) that can be used to
connect an external device (buzzer, relay, alarm
lamp, etc.).
WHITE
(
max
0 mA)
+12V
-
25
S
BLACK
RED
–
12V
–
EXTERNAL
DEVICE
The device must be installed by specialized technical
personnel, as
can jeopardize
its optimal functioning, compromising the safety of the
people present inside the vehicle.
an incorrect positioning
INSTALLATION WARNINGS
The detector must be placed as far away as possible
from cooking appliances to avoid false alarms and
away from openings and ventilation points.
Do not install it near deposits of detergents, solvents,
paints, polishers, etc. because they may release
gases or substances that may compromise the
reliability of the device in the short or long term (e.g.:
acetone, ammonia, alcohol, silicone vapours).
The gas detector has been designed for inside use
only.
Do not install the device outdoors, where it is exposed
to rain or bad weather.
EN