INPUT TECHNICAL DATA
Nominal voltage
Frequency
230Va.c. 10%
±
50÷60 Hz
Maximum power
Protection fuse ref. F2
Security switch
F 2A (glass 5x20)
230Va.c. luminous
250 W
OUTPUT TECHNICAL DATA
Maximum voltage
28,6 Vd.c. (Pb-Gel) - 28,2Vd.c. (Pb-Acido)
Maintenance voltage
Maximum output current
Charge line
IUoU
27,6 Vd.c. (Pb-Gel) - 27,0Vd.c. (Pb-Acido)
8A
Short circuit and inversion polarity protected ref. F1
Thermal protection
Yes
Battery type selector
Pb-Acido / Pb-Gel
15A
)
(car type
GENERAL TECHNICAL DATA
Efficiency
86 %
Room temperature
Ventilation
0 - +50 °C
Automatic regulation variable
Net connection
Security directives
EMC directives
Schuko plug
2006/95/CE
2004/108/CE
Battery connection
Dimensions
Terminals 6,3
180 x 140 x 85 (mm)
Weight
1kg
CHARGING LINE “IUoU”
V = Volt A = Ampere C = Carico - Load
V
I
V I
C
t
I
Uo
U
ST-BY
Uo
GB
7