3.4 Configure the XPORT for Odyssey
To configure the XPORT for Odyssey HMS™, perform the following
procedure in the order presented to ensure proper operation:
1.
After making sure that the MAC address on the VRC2100 sticker
matches the Device Installer
Hardware Address
, double-click the
XPORT-03 that you want to configure.
2.
Access the
Web Configuration
tab and click
Configurable Pins
in
the left pane.
3.
CP0 is not used and can be left with a
Function
setting of
General
Purpose I/O
.
4.
For CP1, select
Modem Control Out
from the
Function
drop-down
list. For CP2, select
Modem Control In
from the
Function
drop-
down list.
Note:
The
Direction
options (
Input
and
Output
) will be disabled
because the direction is inferred by the pin’s In or Out function.
5.
Make sure that the
Active Level
option is set to
Low
for both the
CP1 and CP2.
6.
When you see
Done!
next to the
OK
button, click
Apply Settings
in