background image

Page | 2 

RSA-145E Manual – ABB/Sace Isomax S7 (OTM Mechanism)

 

 

1.0 Installation 

 

DANGER! 

Ensure that the equipment to be remotely operated matches the equipment shown and 
described on the cover page.  If the equipment does not match, please contact CBS 
ArcSafe® for more information regarding remote operating applications for the equipment 
in question. 

 

 

Step 1

: With the MCCB breaker exposed, ensure that the breaker is free from any obstruction 

that may interfere with the proper installation of the RSA-174F. 
 

Step 2:

 Next, prepare the RSA-145E for installation by loosening the two knobs on the lower 

locator.  Also, manually jog the motor arm and attached slide to the position which corresponds 
to the breaker’s current corresponding position (Fully UP for closed position, fully DOWN for 
open position). 
 

Step 3: 

Now, place the RSA-145E around the protrusion on the breaker’s face.  Ensure that the 

RSA assembly sits flush against the lower surface of the breaker before continuing.  NOTE: If the 
MCCB is in the CLOSED position there will be a small tab as shown below, place the RSA 
assembly over this tab during installation as it is spring loaded and depressing it will not affect 
RSA or breaker operation.  

 

 

 

ATTENTION! 

The location of certain items such as mimic bus, stickers, and/or placards may interfere 
with the installation of the remote operating equipment.  These items may need to be 
removed or repositioned for proper installation. 

Reviews:

Related manuals for RSA-145E