ISOBUS Terminal CCI 100/200
– Troubleshooting
76
6 Troubleshooting
6.1 Terminal errors
The following overview shows possible terminal errors and how to solve them:
Error
Possible cause
Rectification
The terminal does not switch
on
•
Terminal is not correctly
connected
•
Check ISOBUS
connection
•
Ignition is not switched on
•
Start tractor
The software of the connected
implement is not displayed
•
Bus terminator missing
•
Check resistance
•
Software is loaded,
however is not displayed
•
Check whether the
software can be
manually started from
the terminal main menu
•
Connection error when
uploading the software
•
Check physical
connection
•
Contact the implement
manufacturer's customer
service
The auxiliary operating unit
(AUX Control) is not shown on
the terminal. An allocation of
implement functions cannot be
made.
•
The terminal is not the
primary terminal on the
bus
•
Configure the terminal
as the primary terminal,
see also chapter
5.3.5.5.4