Map view
121
Overlap tolerance at field boundary
Values between 0 cm and half of the outer section are valid for the
overlap tolerance.
1. Press the "Field boundary overlap tolerance" button.
An input dialogue is displayed.
2. Enter the overlap tolerance.
3. End the Process with "Back".
Warning - General Hazards!
For safety reasons, you should always set a 0% degree of overlap and an over-
lap tolerance of 0 cm at the field boundary.
GPS drift can cause switching on and off of the outer section at the field bounda-
ries. With an overlap tolerance at field border of > 0 cm
you minimise this switching on and off but
may also possibly be working beyond the field boundary.
We recommend the 0 cm setting.
If you set another value, you must check whether working beyond the field
boundary is acceptable.