Troubleshooting
126
10.1
Problems during operation
This chapter lists problems that may occur during use of the terminal.
A suggestion is made for rectification for each problem. If you cannot
rectify the problem based on the suggestion, contact your dealer.
Problem
Cause/remedy
The terminal does not switch
off, if you switch off the trac-
tor ignition.
The tractor does not switch off the supply to the in-cab con-
nector.
Switch the terminal off using the ON/OFF button or
disconnect cable A.
The terminal does not switch
on.
Terminal not connected to the ISOBUS.
The setting up chapter describes how you can connect
the terminal to the ISOBUS.
Ignition is not switched on.
Start the tractor.
The connected implement is
not displayed on the termi-
nal.
Implement is not connected or is incorrectly connected.
Ensure that the implement’s ISOBUS cable is correctly
connected at the tractor.
Bus terminator missing.
Check whether a bus terminator must be attached to the
implement.
Incorrect configuration of the UT.
Configure the UT of the terminal according to this man-
ual.