Troubleshooting
131
37004
Info
/
Incorrect network password
/
You have entered an incorrect WiFi password.
1. Press the button with the name of the WiFi network "WiFi networks" in the
selection list for two seconds.
A context menu is displayed.
2. Select "Edit".
The window for password entry is displayed.
3. Correct the password and confirm your entry.
50000
Caution
/
Implement could not be loaded.
/
The object pool of the implement cannot be displayed clearly by the terminal.
Operation of the implement is thus not possible.
1. Disconnect the implement form the ISOBUS and wait 5 seconds.
2. Reconnect the implement to the ISOBUS.
50001
Caution
/
The connection to the implement is lost.
/
The terminal no longer has a connection to the implement.
You have disconnected the implement from the ISOBUS or
there a connection problem has occurred on the ISOBUS.
1. Check the connection of the implement to the ISOBUS.
50010
Alert
/
The selected UT number is already being used. Please select another UT num-
ber and restart the terminal.
/
The UT is the ISOBUS function for operating ISOBUS implements. Generally
each ISOBUS terminal has a UT. Each UT on the ISOBUS must receive a unique
UT number. Therefore if you operate multiple ISOBUS terminals and thus UTs
on the ISOBUS, then you must assign each UT a unique number.
Note: The CCI 1200 has two UTs.
Note: The UT with which you want to operate the AUX control, must receive the
UT number 1.
The error message appears if two UTs have the same UT number. Change the
UT number of the UT on the CCI 1200 or on the other ISOBUS terminal.
Summary of Contents for CCI 1200
Page 1: ...ISOBUS Terminal CCI 1200 Operating instructions...
Page 2: ......
Page 12: ......
Page 24: ...Setting up for operation 12...
Page 76: ......
Page 112: ......
Page 120: ......
Page 155: ...Index 143 Status bar 22...