Settings
37
You are using the Task Controller of the CCI 1200 and the Task Control-
ler of another ISOBUS terminal.
Each of the two Task Controllers must have a unique number, as other-
wise address conflicts on the ISOBUS may occur.
One ISOBUS implement can only connect to one Task Controller. The
implement selects the task controller based on the task controller num-
ber.
The implement automatically selects
the lowest Task Controller instance or
the Task Controller instance set in the implement.
The number cannot be set in all ISOBUS implements.
1. Press the button "Task Controller instance".
The input dialogue is displayed.
2. Press the button with the number.
The screen keyboard is displayed.
3. Enter the Task Controller instance (number).
4. Confirm your entry.
5. End the Process with "Back".
A message window is displayed.
6. Confirm your entry.
Note
If you change the Task Controller instance (number) of the terminal, you must
also adjust this setting in the ISOBUS implement.
Otherwise the implement does not connect to the Task Controller:
CCI.Config, CCI.Control and CCI.Command will no longer receive any infor-
mation from the ISOBUS implement,
Section Control, Parallel Tracking and Rate Control can no longer be per-
formed.
Task Controller
Number