Implement settings
82
Distance D1
1. Press the button "Distance D1"
An input dialogue is displayed.
2. Enter the Distance D1 in metres.
3. End the Process with "Back".
Distance D1
The distance between the coupling point and the implement reference point:
With trailed implements, the reference point is on the midpoint of the first
axle.
With attached implements, the implement manufacturer specifies the posi-
tion of the reference point.
For manually created implements (e.g. tillage equipment), measure distance
D1 between the coupling point and the last component (e.g. the roller).