Implement settings
83
Section geometry
The following are displayed in the "Section geometry" operating
screen:
The values transferred from the implement and
The delay times corrected on the terminal.
Section geometry
1. Number of sections
The numbering goes from left to right in the direction of travel.
2. Working width of the section
3. Working depth of the section
4. Turn on delay
5. Corrected turn on delay
6. Turn off delay
7. Corrected turn off delay
8. Distance E
The distance between the implement reference point and the midpoint of
the section.
The distance is measured in the direction of travel.
9. Distance F
The distance between the implement reference point and the midpoint of
the section.
The distance is measured perpendicular to the direction of travel.
You have entered the corrected delay times in the terminal. All other values are
displayed as received from the implement.
Note
If you have corrected the turn on delay time or the turn off delay time, Section
Control only considers the corrected delay time.
This delay time is saved in the terminal and not in the implement.