Implement settings
84
Delay times
Set the turn on delay and the turn off delay.
Delay times
The turn on delay time describes the time delay between the command and the
application. During spraying, it is the time from the command "Turn on section"
until the agent is applied.
Where necessary, you can find the turn on delay time in the implement tech-
nical data. In all other cases, you determine the value from your own measure-
ments.
The turn off delay time describes the time delay between the command and the
actual switching off of a section.