CCI.TECU
– Operation
25
4.3.3.4
Speed
This tab shows the number of pulses emitted by the speed sensor over a distance
of 100 metres.
The default setting for the new addition of a tractor shows a value of 13000
Pul/100m.
If the value for the number of pulses per 100 metres is known (e.g. from the sensor
data sheet), this can be entered directly.
In order to obtain information which is as accurate as possible, the value should
actually be obtained using a calibration.
Note
The valid value range for the number of pulses is between 200 and 30000
Pul/100m.
Note
The more accurate the value is, the more precise the speed indication.
You have the following operating options:
Enter the wheel speed sensor value
Enter the ground speed sensor value
Select the hectare counter source
Calibrate