CCI.TECU
– Operation
26
Note
Calibration is only possible for the active tractor. For all other tractors, the button
"Calibrate" (F3) is greyed-out.
4.3.3.4.1 Enter the wheel speed sensor value
Proceed as follows to enter the value for the pulses per 100 metres for the wheel
speed sensor:
1. Press on the "Wheel speed sensor" button on the touchscreen or turn the
scroll wheel until the button is highlighted in white and then press on the scroll
wheel.
Once the button is highlighted you can, alternatively, also press the "OK" (F6)
button.
2. Enter the new value on the touchscreen using the number pad or the slider.
3. Confirm your entry with "OK".
Note
The valid value range for the number of pulses is between 200 and 30000
Pul/100m.
4.3.3.4.2 Enter the ground speed sensor value
Proceed as follows to enter the value for the pulses per 100 metres for the ground
speed sensor:
1. Press on the "Ground speed sensor" button on the touchscreen or turn the
scroll wheel until the button is highlighted in white and then press on the scroll
wheel.
Once the button is highlighted you can, alternatively, also press the "OK" (F6)
button.
2. Enter the new value on the touchscreen using the number pad or the slider.
3. Confirm your entry with "OK".
Note
The valid value range for the number of pulses is between 200 and 30000
Pul/100m.
Summary of Contents for CCI 50
Page 2: ...CCI 50 ISOBUS Terminal Operating instructions Reference Release 5 50...
Page 62: ...55 A Appendix Menu structure...
Page 64: ...CCI Cam Visual implement monitoring Operating instructions Reference CCI Cam v5...
Page 90: ...CCI Control Documentation and task management Operating instructions Reference CCI Control v4...
Page 196: ...107 10 Notes...
Page 199: ...110 Edit 38...
Page 200: ...CCI TECU Tractor data Operating instructions Reference CCI TECU v6...
Page 338: ...CCI GPS GPS settings and tractor geometry Operating instructions Reference CCI GPS v2...