4.3.3.4.4 Calibrate
Note
Where possible the speed calibration should not be carried out on smooth surfaces
(e.g. asphalt), rather directly on the field.
In order to calibrate the speed proceed as follows:
1. Set out a distance of 100 metres.
2. Press the "Calibrate" button (F3) on the touchscreen.
→ A selection list opens.
3. For the calibration select between the wheel and ground speed sensors. To do
this press on the touchscreen button for the sensor whose speed is to be
calibrated or turn the scroll wheel until the button is highlighted in white and
then press on the scroll wheel.
Once the button is highlighted you can, alternatively, also press the "OK" (F6)
button.
Note
The selection between wheel and ground speed sensor for the calibration is only
necessary for a terminal of hardware generation 2 (version 2.x) when both speed
sensors are being used simultaneously (see chapter 4.3.3.3).
→ The calibration menu opens.
4. Go to the starting point and press the "Start Flag" button (F3) on the
touchscreen.
5. Drive 100 metres and then press the "Target Flag" button (F9) on the
touchscreen.
6. Confirm the values with "OK".
Note
The valid value range for the number of pulses is between 200 and 30000
Pul/100m.
Summary of Contents for CCI 50
Page 2: ...CCI 50 ISOBUS Terminal Operating instructions Reference Release 5 50...
Page 62: ...55 A Appendix Menu structure...
Page 64: ...CCI Cam Visual implement monitoring Operating instructions Reference CCI Cam v5...
Page 90: ...CCI Control Documentation and task management Operating instructions Reference CCI Control v4...
Page 196: ...107 10 Notes...
Page 199: ...110 Edit 38...
Page 200: ...CCI TECU Tractor data Operating instructions Reference CCI TECU v6...
Page 338: ...CCI GPS GPS settings and tractor geometry Operating instructions Reference CCI GPS v2...