CCI.Command
– Operation
31
Delay times
The
delay times
describe the time delay between the command and the actual
activation of a section (e.g. during spraying, the time from the command: "Switch
on section", until when the agent is actually applied).
There is a
switch-on
and a
switch-off delay
.
4.3.3.4
Enter delay times
Note
If the
delay times
are transferred from the implement, the buttons are greyed out.
Manual entry is not possible.
The implement
delay times
are displayed in the Section geometry view (see
chapter 4.3.3.1).
To change the
delay times
, the implement operation must be called up. You can
find more information in the operating instructions for your implement.
To enter the
delay times
, proceed as follows:
1. In the
touchscreen
press on the buttons "Switch-on delay" (button 3) and
"Switch-off delay" (button 4) and enter the times that must be adhered to
before individual selections are switched on or off.
2. Confirm your entry with "OK".
Note
Values between 0.00 and 10.00 seconds are valid for the
Delay times
.
Summary of Contents for CCI 50
Page 2: ...CCI 50 ISOBUS Terminal Operating instructions Reference Release 5 50...
Page 62: ...55 A Appendix Menu structure...
Page 64: ...CCI Cam Visual implement monitoring Operating instructions Reference CCI Cam v5...
Page 90: ...CCI Control Documentation and task management Operating instructions Reference CCI Control v4...
Page 196: ...107 10 Notes...
Page 199: ...110 Edit 38...
Page 200: ...CCI TECU Tractor data Operating instructions Reference CCI TECU v6...
Page 338: ...CCI GPS GPS settings and tractor geometry Operating instructions Reference CCI GPS v2...