Contents 

Technical Data ......................................................................................................... 2

 

Overview ................................................................................................................. 2

 

Equipment Description.............................................................................................. 3

 

Installation............................................................................................................... 4

 

Start-up ................................................................................................................... 6

 

Calibration ............................................................................................................... 7

 

Operation................................................................................................................. 8

 

Maintenance .......................................................................................................... 11

 

 

 

Reference 

Version 

Date 

MPET0219 

v1.0 

19/02/2014 

Technical Manual v1.0 

Warning 

Carefully read this manual 

before installing, starting or 

using this device. 

Limpido

EZ

 

Duo 

Electrolysis  & 
pH regulation 

Summary of Contents for Limpido EZ DUO 60

Page 1: ...Installation 4 Start up 6 Calibration 7 Operation 8 Maintenance 11 Reference Version Date MPET0219 v1 0 19 02 2014 Technical Manual v1 0 Warning Carefully read this manual before installing starting o...

Page 2: ...dissolves immediately in the water producing hydrochlorous acid HClO This powerful disinfectant destroys bacteria and algae before it retransforms into salt The amount of chlorine needed to disinfect...

Page 3: ...in the pH of the water between 7 0 and 7 6 For information the table to the right allows determining the required production time versus the basin volume the pH for a water temperature of 25 C Since t...

Page 4: ...he detector must be pointing in the direction of the water s flow COVER CONTACT This input must be connected to the drycontact of the cover s travel limit switch or the pool s flap Thecontact must be...

Page 5: ...reasons the Limpido EZ Duo box must be installed more than 3 50 m from the pool edge The box must be placed on a flat stable support It must be supplied with a single phase 230V 50Hz power supply and...

Page 6: ...chlorine from the degradation that the sun s ultraviolet UV radiation subjects it to On the other hand this cyanuric acid is not consumed and inexorably accumulates in pools treated with chlorine pebb...

Page 7: ...he central indicator light green turns on Turn to the minus sign if the left indicator light red is lit Turn to the plus sign if the right indicator light red is lit When the central indicator light g...

Page 8: ...CHOICE In Automatic mode pressing and holding down the key for 3 seconds allows changing the adapted thermoregulation curve The indicator light corresponding to the active curve flashes To select the...

Page 9: ...dic flash Water temperature too low to produce 10 C 5 periodic flashes Filtration insufficient Forced filtration Permanently flashing Temperature measurement error POLARITY INDICATOR The cell is clean...

Page 10: ...if Limpido EZ Duo could not produce throughout the required time despite forced operation the device signals underproduction by flashing the indicator light In this case the daily filtration time shou...

Page 11: ...to keep the cell from operating in a water with too low a salt content 2g l In case a tarpaulin or a cover is used the chlorine is protected from UV radiation To prevent an over chlorination the prod...

Page 12: ...laration The Bleu Electrique SAS Company FR 47 403 521 693 declares that the LIMPIDO EZ Duo product satisfies the safety and electromagnetic compatibility requirements of the European directives 2006...