6.3.2. Messages
Alternating with the status screen (screen saver) described above, the Limpido XC2 gives the user
information to help prevent possible anomalies or to troubleshoot a possible fault. Messages are
then displayed alternating with the device status:
Message
Description
Solution
Wait for flow
Waiting for filtering
to be detected.
This message should only appear when
there is no flow detected through the cell.
If this message appears when the filter-
ing is running, check the valve positions
and flow detector installation (bad contact
on the electric connection, damper jammed
due to a too small hole in the piping, etc.).
Error temp
Water temperature
measurement error
Check the cell connection
Low salt
Current too weak /
not enough salt
Check the salt level If the fault persists even
though the salt level is correct, check the
cell condition
Descale the cell using diluted acid
Add salt after having confirmed the need.
Please refer to the electrolysis section.
This fault may just be caused by the tempo-
rary presence of air in the cell following the
filtering pump becoming unprimed or an air
leak somewhere on the circuit.
Too much salt
Current too strong /
too much salt
Check the salt level
Change part of the water
Please refer to the electrolysis section.
Increase Filtr.
Over the past 24
hours the filtering
system has not been
detected for long
enough for the elec-
trolysis device to
produce during the
programmed / calcu-
lated time.
Adapt filtering time to production needs.
The fault will only disappear after 24 hours
on condition that the electrolysis unit has
been able to produce for the programmed
time.
SUPERVISOR
This message is displayed briefly when entering supervisor mode
(see 6.10).