background image

LIMPIDO Z : 

QUICK START

QUICK START 

OF THE DEVICE :

HIGH OR LOW SALT LEVEL WARNINGS & BACKWASH

ENTER 

ELECTROLYSE MENU

For a quick and efficient start of  the electrolysis system, use the mode 

Production=ON

. This mode will allow to 

control the device together with the filtration system.
 
 

ENTER 

pH MENU

Set regulation on pH 

Dosage ph = pH- 

to bring pH down.

Set regulation on pH 

Dosage ph = pH+ 

to bring pH up.

 The 

pH=ON

 mode is a continuous functioning mode which must be used only for pump priming.

 

NEVER LEAVE THIS SETTING ON

, otherwise the pH bottle would empty quickly.

The device is provided with a safety on pH injection, which allows to set a maximum daily volume not to be 
exceeded. For example, in a 40m3 pool, a daily dose of  0.3 litre/24h is enough. This setting can be done in the 
pH menu: 

V/24h=0.3L

.

SHORT  FILTRATION POWER CUTS :

Warning : short power cuts (less than 1 minute) on the filtration pump or on 230V may lead to default of  
the device. This default  stops chlorine production but is not harmful to the device

When you face « lack of  salt » of  « high salt level », cut off  the device for 5 minutes, then restart
the device after checking the electrolysis setting is not OFF. This operation can be enough to remove 
the warning. If  the default remains, check the real salt level into the pool as described in page 6 of  the 
user’s guide.

IN CASE OF BACKWASH :

Turn off  the device while backwashing the filter. The device should remain turned off  during backwash 
(5 minutes)

For a correct setup of  the probes, use 
ZELIA-POD and connect the ground socket 
of  the  ZELIA-POD on a ground rod which 
is independent from the safety ground 
equipment of  the house. This independent 
ground system must be as good as pos-
sible in order to increase the efficiency of  
the probes (reading and lifetime).

USING INSTRUCTIONS

Injection pH

pH injection

Sonde pH

pH probe

Sonde ORP

ORP probe

PoolTerre intégré

Earthing device

Z3

Only

For a more precise electrolysis, use the mode 

Production=REG

 which will allow to control chlorine 

production according to pool RedOx. See the instructions leaflet, on page 12 to buffer the RedOx probe and 
to set the RedOx set value

Reviews: