The electrical connection must be performed dry, in a sealed
connection box whose cable glands must be tightened in order
to avoid any water infiltration.
4. Cable Cross-Section
CROSS-SECTION (mm²)
1,5
2,5
4
6
The voltage drop in the supply cable of the
Mini Brio M12 (&12K, 12B) & 12HW ca-
ble should be limited in order to comply
with the applicable standards and ensure
optimal illumination.
Follow the table opposite (one projector
per cable);
Max. length
(m)
16 (M12)
26.7 (M12) 42.7 (M12)
64 (M12)
5. Projector Protection
Independent protection is necessary for each Mini Brio M12 (&12K, 12B) & 12HW. Protection must be ensured in the secondary
of the transformer using fuses or breakers at 2A or 3A.