Technical instructions
MPZ
v1.1
www.ccei.fr
9
Switch
no. 4
Switch
no. 5
Switch
no. 6
RGB mark-
er ("off" in
normal oper-
ating mode)
Signalling the
status of the
output points
(when active)
Confirmation
flash colour (in
programming)
Number of
flashes of the
module indi-
cator (in pro-
gramming)
OFF
OFF
OFF
Marker deacti-
vated
fixed
Red
1
OFF
OFF
ON
Regular
white
flashes
fixed
Green
2
OFF
ON
OFF
Regular
white
flashes
flashing
Yellow
3
OFF
ON
ON
Rainbow:
per-
manent
colour
gradient
flashing
Blue
4
ON
OFF
OFF
White fade out in
a loop
fixed
Magenta
5
ON
OFF
ON
White fade out in
a loop
flashing
Cyan
6