Technical instructions
WEX30
v40EN
6. Electrical Connections
Installation of this product involves a hazard of electric shocks. We strongly recommend you
contract a professional installer. Incorrect installation places you in danger and may irre-
versibly damage the product and the equipment connected to it. In compliance with the NF C
15-100 standard, pool lights installed in Volume 0 must always be powered with SELV (Safety
Extra Low Voltage). Always cut off the power upstream before handling the electrical instal-
lation.
Risk of electric shock. Only connect to a circuit which is protected by a ground-fault circuit
interrupter. If you are not sure if these types of devices are fitted, contact a qualified electrician.
A. standard PAR56 niche
B. PAR56 bulb support
C. Seal to crush during light installation. This guarantees the tightness of the electrical connection.
D. 12V AC Power supply. The cable must be equipped with "eye" or "fork" terminal plugs for a proper
connection (Ø 4 mm)
Refer to the user guide of the niche to replace the bulb.
The arrow in front of the bulb must be placed on top during installation.
www.c-
cei.fr
3