6. Electrical Connections

Installation of this product involves a hazard of electric shocks. We strongly recommend you
contract  a  professional  installer.  Incorrect  installation  places  you  in  danger  and  may  irre-
versibly damage the product and the equipment connected to it. In compliance with the NF C
15-100 standard, pool lights installed in Volume 0 must always be powered with SELV (Safety
Extra Low Voltage). Always cut off the power upstream before handling the electrical instal-
lation.

Risk of electric shock. Only connect to a circuit which is protected by a ground-fault circuit
interrupter. If you are not sure if these types of devices are fitted, contact a qualified electrician.

A. standard PAR56 niche

B. PAR56 bulb support

C. Seal to crush during light installation. This guarantees the tightness of the electrical connection.

D. 12V AC Power supply. The cable must be equipped with "eye" or "fork" terminal plugs for a proper

connection (Ø 4 mm)

Refer to the user guide of the niche to replace the bulb.

The arrow in front of the bulb must be placed on top during installation.

www.c-

cei.fr

3

Summary of Contents for WEX30

Page 1: ...eatures Sizes Standard PAR 56 Installation In standard PAR 56 niche Power supply 12 V AC 50Hz 60Hz Power consumed 40W maximum according to colour LED type 9 powerful monochrome LEDs 3R 3G 3B 6 MidPower cool white LEDs 6000 K Risk group 1 low risk according to IEC62471 2006 Protection index IP 68 after installation Max luminous flux According to colour 1150 lm maxi white Color control RC RC BT or b...

Page 2: ...programmes with shorts cutting power supply Change of mode A small cut of power supply less than 1s switches to the next colour sequence Once all the colours are displayed the light goes back to the first colour pure white A cut of supply 2s resets the light synchronization and switches them to second colour blue After a long stop more than 4s the lights show the last displayed colour Fixed colour...

Page 3: ...he power upstream before handling the electrical instal lation Risk of electric shock Only connect to a circuit which is protected by a ground fault circuit interrupter If you are not sure if these types of devices are fitted contact a qualified electrician A standard PAR56 niche B PAR56 bulb support C Seal to crush during light installation This guarantees the tightness of the electrical connecti...

Page 4: ...e of the WEX30 must be limited so that the colours are not altered Respect the table opposite one projector per cable Max length m 10 0 17 0 25 6 42 6 A Connection schematic B Declaration of conformity Bleu Electrique SAS FR47403521693 declares that product WEX30 is compliant with the safety and electromagnetic compatibility requirements of European directives 2006 95 CE and 2004 108 CE Emmanuel B...

Reviews: