                                                                          Contents

  

 

 

 

 

                                                                

Introduction 
Installation 
Terminologies Used 
Programming the PBX 
Allowed Table 
Auto Attendant Settings 
Auto Call Back 
Auto Call Disconnection 
Barge-In 
Call Forward 
Call Pick-Up 
Checking Extension Number 
CLI (Calling Line Identification)  
CLI Transferable / Internal 
CLI 

– Digits addition 

CLI Receiving Mode (DTMF / FSK)  
CLI Transmitting Mode (DTMF) 
Conference with 1 Junction & 1 Ext 
Conference with 2 Junctions 
Day / Night Mode 
Denied Table 

– A 

Denied Table 

– B 

Do Not Disturb (DND) 
Door Phone 

  Emergency Call 
  Extension to Extension call 

Flash Time setting 
Flexible Numbering  
Hot Line to Junction  
Hot Line to Extension 
Junction Access during Power Failure 
Junction Access Control 
Junction Line Ring Assignment  
Junction Line- Enable / Disable  

Summary of Contents for 216B

Page 1: ...d Table Auto Attendant Settings Auto Call Back Auto Call Disconnection Barge In Call Forward Call Pick Up Checking Extension Number CLI Calling Line Identification CLI Transferable Internal CLI Digits...

Page 2: ...able them refer heading Junction Line Enable Disable Model 216B has 2 CO Lines 16 Extensions Model 224B has 2 CO Lines 24 Extensions Model 232B has 2 CO Lines 32 Extensions Installation Cabling All ca...

Page 3: ...ming the PBX To program most of the feature mentio n ed in this manual program ming Passwo rd is to be entered from any extensio ns 601 602 603 604 through the following command 0000 Here 0000 is the...

Page 4: ...anding 0000 1666 d Play Welcom e Messag e again 0000 1665 Default Call is transf erred to Operator Auto Call Back From Busy Junction Lines To get a call back when any of the busy Junctio n lines get f...

Page 5: ...e changed using the following program Dial 0000 184 TT Where TT 01 99 Ring Time in seconds Default value 20 secs Note The time entered here should be less than the Internal Call Ringing Time Call Pick...

Page 6: ...Day Night Mode The PBX can be configured in 2 sets of program ming One for the day mode and one for the night mode To change the system to Day Mode Dial 20 To change the system to Night Mode Dial 21...

Page 7: ...gits 0 7 8 and 9 Procedure Dial 0000 9000 This also resets all the flexible numbering of the PBX Dial 0000 9 NN ABCD Where N Last two digits of the original extensio n numbe r This original number alw...

Page 8: ...otted Junctio n number 02 will be allotted only when Junctio n 01 is engaged Program ming To program in Circular mode Dial 0000 0620 To program in Sequential mode Dial 0000 0621 Junction Access Contro...

Page 9: ...this delay time Dial 0000 03 TT Where TT 01 to 99 secs Default value 07 7 secs Junction Line Ring Assignment Junctio n lines incoming ring can be set in the Direct ring modes Direct Ring Mode Calls l...

Page 10: ...tion lines will hear a tone after 2 minutes and if any of them presses then they can talk for another 2 minutes Like this they can keep extending the talk time If is not pressed then the calls will di...

Page 11: ...Default Value 99 secs Troubleshooting Problem Solution No Dial tone on any extension 1 Check power cable is tightly inserted No Run LED 2 Check fuse by unscrewing from cabinet 3 Open system check if...

Page 12: ...ice personnel for carrying out repairs or maintenance and the same would be attended within a reasonable response time assigned to the dealer 8 The consumer will be billed for parts or labor charges n...