19
Internal Call Ringing Time
This is the time for which an extension keeps ringing when an Extension call another Extension.
Program
:
Dial #
0000 + 494 TT #
Where, TT= 01-99 secs (Default Value = 99 secs)
Auto Attendant Voice Message mode ringing time
This is the time for which an extension rings when the out side caller dials an Extension number in Auto Attendant Voice
Message mode.
Then the call shifts to Operator or as defined under the heading “Auto Attendant Voice message of 8
Secs” or “Auto Attendant Voice message of 20 Secs”
Program
:
Dial #
0000 + 496 TT #
Where, TT= 01-99 secs (Default Value = 40 secs)
01 to 10 stands for 1 Sec to 10 secs
.
SD-Card and Paging Card Enabling (Optional)
When ONLY 4 Junctions are installed in system, Paging Card and SD Card can be installed.
But in this case, Extension 15 and 16 get disabled.
Dial #* 0000 + 885 X #
Where X = 0, Extension 15 and 16 will work as normal. SD Card + Paging Card can be used with 8 Junctions installed.
(Default)
X =1, Extensions 15 and 16 get disabled. SD Card can be used with ONLY 4 Junctions installed.
Setting on Main Board:
To use SD Card with only 4 junctions:
-
Open jumper “JM1”. This will disable Ext 15.
-
Switch ON 2 on DIP switch
To use Paging with only 4 junctions:
-
Open jumper “JM2”. This will disable Ext 16.
-
Switch ON 3 on DIP switch
Default :
DIP switch 2 and 3 are OFF.
Jumpers JM1 and JM2 are shorted.
.
SD-Card Playing mode (Optional)
To set SD-Card Playing mode-
Dial #* 0000 + 24 X #
Where X = 0, for None/Not Available (Default)
X =1, for Auto Attendant
X=2, for Hold Music
.
UCD Group
Two UCD group can be set for termination in case of multilayer auto attendant. To set UCD group-
#* 0000 + 26 G nn1,nn2,….,nn5 #
Where G= group number (1-2)
nn1 - nn5, - last two digit of ext number (Max 5 ext can be defined in a UCD group)
.
Troubleshooting
.
Problem Solution
There is no ring on any extension Press RESET Switch (next to the relay) on the SMPS card of the PBX, twice.
The Power LED on the front panel Re-insert the connectors of the lead that connects
Is ON but there is no dial tone on the SMPS card to the main card of the PBX.
any extension. Re-insert the connectors at both ends of the lead.
.
Testing & Debugging (For Service Engineer) )
.
Test all Ports:
# * 0000 188 N # where, N= 0 to Disable
= 1 to Enable
Note: This setting gets disabled automatically after power off.
On enabling, every extension gets a short ring after on-hook.
.
Technical Specifications
.
Switching
Space Division Multiplexing
Power Supply
SMPS type
Input
AC 80V to 260V