11
3) Terminal Block
[Figure 2-2. COBRA ELITE 960H-16CH Terminal Block and Description]
The terminal blocks in the rear of the product are for the connection of PTZ / Sensor / Relay / POS Connection.
The number of the terminal block may be different depending on the model.
①
PTZ Camera/Keyboard Controller
Connect PTZ control cable; TRX+, TRX- and GND to Terminal Block(TB1);No.4 TRXD+, No.5 TRXD- and No.10
GND in the rear of DVR. You may refer to APPENDIX for supported PTZ cameras in this manual. Keyboard
controller has the same connection as PTZ camera.
PTZ Camera may not be working properly if GND is not connected.
②
Sensor/Relay /POS
Connect Sensor/Relay/POS to the terminal block directly depending on the model.
Sensor and Relay Type
NC(Normal Close)
: Normally closed; opens when a signal is received
NO(Normal Open)
: Normally open; closes when a signal is received
(1) Sensor Connection
①
Connect the sensor to the terminal block S1 ~ S16 depending on the model.
②
Each input terminal is connected relatively with the channel number.
(2) Relay Connection
③
Relay the output signal to external devices such as Alarm and Siren.
④
Connect the relay to R1/R2/R3/R4 terminal block depending on the model
Summary of Contents for Cobra Elite 960H